You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PRDMXSN912


$281.85 USD
  • SUN HYDRAULICS
  • Material:PRDMXSN912
  • Model:PRDM-XSN@912
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXSN912 (PRDMXSN912) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure in various systems. This valve reduces high primary pressure at the inlet port 2 to a consistent reduced pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. Engineered for reliability, the valve operates by connecting port 2 to port 1 at a specified pressure setting, with increasing current to the coil proportionally decreasing the reduced pressure at port 1. It offers excellent pressure control and dynamic response, as it remains open during the transition from reducing to relieving modes. Pressure at port 3 is additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar) for optimal performance. The direct-acting concept ensures highly reliable operation even in contaminated systems, especially under dead-headed conditions. For enhanced performance, an amplifier with current sensing and adjustable dither between 100-250 Hz is recommended. The valve's interchangeable coils can be mounted on the tube in either direction, providing flexibility in installation. With no electrical signal, the valve defaults to a customer-specified reduced pressure setting. It allows full reverse flow from reduced pressure port 1 to inlet port 2 but may require an additional check valve if reverse free flow is needed. All three-port cartridges are physically interchangeable for ease of integration into existing systems. The Sun floating style construction minimizes internal binding risks due to excessive installation torque or machining variations. The PRDMXSN912 has a capacity of 5 gpm (20 L/min) and can handle maximum operating pressures up to 5000 psi (350 bar). It features minimal leakage rates and requires specific installation torque values for optimal performance.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)20 in³/min.330 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006