  • Model:PRDN-XDV@712
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDNXDV712 (PRDNXDV712) is an electroproportional, direct-acting reducer-reliever valve designed to reduce high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while offering a full flow relief function from port 1 to tank port 3. The valve operates in a reducing mode by default, connecting port 2 to port 1 at a customer-specified pressure setting. When electrical current is applied to the coil, it proportionally decreases the reduced pressure at port 1. If the pressure at port 1 surpasses the coil-induced setting, it is relieved to port 3. The valve's transition between reducing and relieving modes is closed, resulting in minimal oil consumption. For optimal performance, this valve should be used with an amplifier featuring current sensing and adjustable dither between 100 and 250 Hz. The coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the tube. In scenarios without an electrical signal, the reduced pressure defaults to the pre-set customer value; increasing the coil command reduces secondary pressure proportionately. This valve is particularly suitable for accumulator circuits due to its design that minimizes secondary circuit leakage by eliminating pilot control flow. Its direct-acting concept ensures reliable operation even in contaminated systems or dead-headed conditions. However, reverse flow from reduced pressure port 1 to inlet port 2 may close the main spool; thus, incorporating a separate check valve may be necessary if reverse free flow is required. The PRDNXDV712 features Sun's floating style construction to reduce internal part binding risks due to installation torque or cavity-cartridge machining variations. It supports a maximum operating pressure of up to 5000 psi (350 bar) and maintains low leakage rates.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is closed in the transition between reducing and relieving resulting in very low consumption of oil.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • The transition from reducing to relieving is closed. The result is very low leakage. However, there is a transitional step increase in pressure between reducing and relieving modes. This step equals about 5% of the high end of the adjustment range, independent of the valve setting.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)2.5 in³/min.41 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006