***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDNXEV224 (PRDNXEV224) is an electroproportional, direct-acting reducer-reliever valve designed to manage hydraulic pressure efficiently. It operates by reducing a high primary pressure at inlet port 2 to a constant, reduced pressure at port 1, while providing a full flow relief function from port 1 to tank port 3. This valve is particularly effective in systems where low oil consumption is crucial, as it remains closed during the transition between reducing and relieving pressures. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar), with any pressure at this port being directly additive to the valve setting. The valve's leakage characteristics are influenced by the viscosity and pressure differential, with minimal leakage due to its closed transition design. For optimal performance, it is recommended to use an amplifier with adjustable dither between 100-250 Hz and current sensing capabilities. The coils are interchangeable with Sun's other solenoid-operated valves and can be mounted in either direction on the tube. In case of no electrical signal, the valve defaults to a customer-specified reduced pressure setting, which can be adjusted proportionally by increasing the command signal to the coil. This valve is suitable for accumulator circuits due to its design that minimizes secondary circuit leakage without pilot control flow. It also incorporates Sun's floating style construction, which reduces internal binding risks due to installation torque or machining variations. When considering reverse flow in circuits using this valve, adding a separate check valve may be necessary if free reverse flow is required from reduced pressure port 1 back to inlet port 2. With physical interchangeability among three-port cartridges of similar frame size, this model offers flexibility in mounting configurations with full capacity return line considerations for reducing-relieving applications.
The Sun Hydraulics PRDNXEV224 (PRDNXEV224) is an electroproportional, direct-acting reducer-reliever valve designed to manage hydraulic pressure efficiently. It operates by reducing a high primary pressure at inlet port 2 to a constant, reduced pressure at port 1, while providing a full flow relief function from port 1 to tank port 3. This valve is particularly effective in systems where low oil consumption is crucial, as it remains closed during the transition between reducing and relieving pressures. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar), with any pressure at this port being directly additive to the valve setting. The valve's leakage characteristics are influenced by the viscosity and pressure differential, with minimal leakage due to its closed transition design. For optimal performance, it is recommended to use an amplifier with adjustable dither between 100-250 Hz and current sensing capabilities. The coils are interchangeable with Sun's other solenoid-operated valves and can be mounted in either direction on the tube. In case of no electrical signal, the valve defaults to a customer-specified reduced pressure setting, which can be adjusted proportionally by increasing the command signal to the coil. This valve is suitable for accumulator circuits due to its design that minimizes secondary circuit leakage without pilot control flow. It also incorporates Sun's floating style construction, which reduces internal binding risks due to installation torque or machining variations. When considering reverse flow in circuits using this valve, adding a separate check valve may be necessary if free reverse flow is required from reduced pressure port 1 back to inlet port 2. With physical interchangeability among three-port cartridges of similar frame size, this model offers flexibility in mounting configurations with full capacity return line considerations for reducing-relieving applications.
This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is closed in the transition between reducing and relieving resulting in very low consumption of oil.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- The transition from reducing to relieving is closed. The result is very low leakage. However, there is a transitional step increase in pressure between reducing and relieving modes. This step equals about 5% of the high end of the adjustment range, independent of the valve setting.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
- Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 5 gpm20 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2.5 in³/min.41 cc/min. |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.20 lb0,55 kg |
| Seal kit - Cartridge | Viton: 990-511-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Weatherized Solenoid Valves for Harsh Environments
- Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Electro-Proportional Basics Explained
- Proportional Amplifiers and Ancillary Products
- Manufacturing Sun Cartridge Cavities
- Solenoid Coils for Switching and Proportional Valves
- Reducing and Reducing/Relieving Valves
- Electro-Proportional Cartridge Valves
- Electro-Proportional Terms and Definitions
- Cavity Information (S-171) and Tooling
- Sun's Floating Style Screw-In Cartridge
- Fluid and Temperature Recommendations
- Sun Model Code Explanation; 999-901-334
- Performance Data
- Cartridges: Materials of Construction
- Units of Measure, Settings, and Conversions