***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDNXEV624 (PRDNXEV624) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure in complex systems. This valve functions by reducing a high primary pressure at inlet port 2 to a constant reduced pressure at port 1, and includes a full flow relief function from port 1 to tank port 3. It operates in the reducing mode by default, connecting ports 2 and 1 at a specified pressure setting. Increasing the electrical current to the coil proportionally decreases the reduced pressure at port 1. Should the pressure at port 1 exceed the coil-induced setting, it is relieved to port 3. The transition between reducing and relieving is closed, minimizing oil consumption and leakage. The valve's maximum allowable pressure at port 3 is capped at 3000 psi (210 bar), with any increase directly adding to the valve setting. Leakage occurs out of port 3 under specific conditions and is proportional to pressure differential while inversely proportional to viscosity. A transitional step increase in pressure occurs between modes, independent of valve settings, equating to about five percent of the adjustment range's high end. For optimal performance, use an amplifier with current sensing and adjustable dither between 100 - 250 Hz. Coils are interchangeable with other Sun solenoid-operated valves and can be mounted bidirectionally on the tube. With no electrical signal, it defaults to a customer-specified reduced pressure setting; increasing command reduces secondary pressure proportionally. Suitable for accumulator circuits due to low pilot control flow leakage, this direct-acting concept ensures reliable operation even in contaminated systems or dead-headed conditions. Consider adding a separate check valve for reverse free flow requirements as reverse flow may close the main spool. All three-port cartridges are physically interchangeable within frame sizes for versatile mounting configurations while using Sun's floating style construction minimizes internal part binding risks due to installation torque or machining variations.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is closed in the transition between reducing and relieving resulting in very low consumption of oil.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • The transition from reducing to relieving is closed. The result is very low leakage. However, there is a transitional step increase in pressure between reducing and relieving modes. This step equals about 5% of the high end of the adjustment range, independent of the valve setting.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)2.5 in³/min.41 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006