***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDRODV (PRDRODV) is a direct-acting pressure reducing valve designed to lower a high primary pressure at inlet port 2 to a consistent reduced pressure at port 1. This valve is engineered with a damped construction, allowing it to maintain stable operation even when using high reduced pressures. It is important to note that this valve lacks relieving capability and should not be used in deadheaded applications, as the pressure on the reduced side may increase significantly due to low leakage. The PRDRODV is an ideal replacement for an LPC valve when a normally open, restrictive compensating element with a higher pressure drop across an orifice is required. This model features EPDM seals suitable for systems using phosphate ester fluids, though exposure to petroleum-based substances can damage these seals. It incorporates Sun's floating style construction which minimizes internal part binding due to excessive installation torque or cavity/cartridge machining variations. The valve supports full reverse flow from port 1 back to port 2; however, this may cause the main spool to close unless a separate check valve is added for reverse free flow. The PRDRODV performs well in accumulator circuits because it reduces secondary circuit leakage by eliminating pilot control flow. It offers superior dynamic response compared to equivalent pilot-operated models and maintains correct operation under maximum operating pressures of up to 5000 psi (350 bar). Pressure at port 3 directly adds to the valve setting at a 1:1 ratio but should not exceed the maximum limit of 5000 psi (350 bar). The cartridge's capacity is rated at 10 gpm (40 L/min), and it has been factory tested for optimal performance with various spring ranges and inlet pressures.

Direct-acting, pressure reducing valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1. These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Note: This valve has no relieving capability. It should not be used in a dead-headed application. If the reduced pressure side of the circuit has very low leakage the pressure may rise significantly. The pressure rise will vary from valve to valve.
  • This type of valve, PR*R, is a good replacement for an LP*C as a normally open, restrictive compensating element if a higher pressure drop across an orifice is needed.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established at2 in³/min.30 cc/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.30 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.