SUN HYDRAULICS
PRFBCDV


$142.27 USD
  • SUN HYDRAULICS
  • Material:PRFBCDV
  • Model:PRFB-CDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRFBCDV (Material Number: PRFBCDV) is a direct-acting, pressure-reducing and relieving valve designed to maintain a constant reduced pressure at port 1 while providing a full-flow relief function from port 1 to tank port 3. This valve features a damped construction for stable operation, making it suitable for high-pressure applications up to 5000 psi (350 bar). The pressure at port 3 is additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). Leakage from port 3 is proportional to the pressure differential and inversely proportional to fluid viscosity. The PRFBCDV model is interchangeable with other three-port reducing and relieving cartridges of the same frame size, allowing for flexible mounting configurations. It supports full reverse flow from reduced pressure port 1 to inlet port 2; however, adding a separate check valve may be necessary if reverse free flow is required in the circuit. This valve's direct-acting design ensures reliable performance in contaminated systems and offers superior dynamic response compared to pilot-operated models. It incorporates Sun's floating style construction, minimizing internal part binding due to installation torque or machining variations. The valve accommodates accumulator circuits with reduced secondary circuit leakage due to the absence of pilot control flow. It features an adjustment range with five clockwise turns available for increasing settings, tested for correct operation with inlet pressures up to 5000 psi (350 bar). The PRFBCDV comes with specific installation requirements including torque specifications and seal kit compatibility (Viton: 990202006), ensuring optimal performance across various hydraulic applications.

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgeViton: 990-202-006