SUN HYDRAULICS
PRFBKDN


$140.29 USD
  • SUN HYDRAULICS
  • Material:PRFBKDN
  • Model:PRFB-KDN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRFBKDN (Material Number: PRFBKDN) is a direct-acting, pressure reducing-relieving valve designed to maintain a constant reduced pressure at port 1 from a higher primary pressure at the inlet port 2, with a full-flow relief function to tank port 3. This valve features a damped construction for stable operation, allowing the use of high reduced pressures. It is compatible with accumulator circuits due to its design that reduces secondary circuit leakage without pilot control flow. The valve's direct-acting mechanism ensures reliable performance in contaminated systems and exhibits superior dynamic response compared to pilot-operated models. The PRFBKDN model uses Sun's floating style construction, minimizing internal parts binding from excessive installation torque or machining variations. It operates efficiently under pressures up to 5000 psi (350 bar) and is suitable for applications requiring stable and reliable pressure control. The valve's design allows for full reverse flow from reduced pressure port 1 to inlet port 2, although adding a separate check valve is recommended if reverse free flow is needed in the circuit. Its cavity type T-2A and series 2 capacity allow for up to 20 gpm (80 L/min) flow rates. This model incorporates adjustable settings with five clockwise turns needed to increase the setting, and its construction supports applications requiring maximum operating pressures while maintaining minimal leakage rates of approximately 3 in\u00b3/min (50 cc/min) at specified viscosities. The Sun Hydraulics PRFBKDN model provides robust performance, making it suitable for various hydraulic circuits needing precise pressure regulation without compromising on stability or reliability.

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ