You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PSDBOEN


$127.08 USD
  • SUN HYDRAULICS
  • Material:PSDBOEN
  • Model:PSDB-OEN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PSDBOEN (PSDBOEN) is a direct-acting pressure reducing/relieving valve designed to manage high primary pressures at the inlet port and maintain a consistent reduced pressure at the outlet port, while offering full flow relief to the tank port. This valve features a damped construction for stable operations, making it suitable for systems that require high reduced pressures. It is particularly effective in accumulator circuits due to its ability to minimize secondary circuit leakage, thanks to the absence of pilot control flow. With a maximum operating pressure of 5000 psi (350 bar) and tested spring ranges up to 5000 psi inlet pressure, this valve ensures highly reliable performance even in contaminated environments. The PSDBOEN valve incorporates Sun's floating style construction, reducing the risk of internal binding caused by excessive torque or machining variations. While it provides superior dynamic response compared to pilot-operated models, users should be aware of its transitional step between reducing and relieving modes, which may not suit counterbalancing applications. The valve's design also allows for pressure adjustments via an internal hex screw and locknut, with specific torque requirements for installation. For optimal performance, the maximum pressure at port 3 should not exceed 3000 psi (210 bar), and any backflow from reduced pressure port 1 to inlet port 2 may necessitate an additional check valve in the circuit. The PSDBOEN model also offers adaptability by controlling drain port pressure to increase effective valve settings beyond nominal values. Its compact design includes a cavity T-21A series with a capacity of 10 gpm (40 L/min), making it versatile for various hydraulic applications where precise pressure control is critical.

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining port 4 makes the valve insensitive to pressure at port 3. These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-021-006

Show FAQ

Additional Resources



Notes: