PVDALEV
$123.90 USD
- SUN HYDRAULICS
- Material:PVDALEV
- Model:PVDA-LEV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVDALEV (Material Number: PVDALEV) is an externally drained, pilot-operated pressure reducing and relieving valve designed to maintain a constant reduced pressure at port 1 from a high primary pressure at inlet port 2, while offering a full-flow relief function to tank port 3. This valve is insensitive to pressure at tank port 3 due to its external pilot section drainage at port 4, allowing for remote control by pilot or two-way valves. With a maximum operating pressure of 5000 psi (350 bar), the PVDALEV exhibits low deadband transition between reducing and relieving modes and features exceptionally flat pressure-flow characteristics for stability and low hysteresis. The valve's design incorporates Sun\u2019s floating style construction to minimize internal binding due to installation torque or machining variations. The recommended maximum inlet pressure varies with the adjustment range, tested with differentials of up to 5000 psi (350 bar) for ranges C and W. The valve allows reverse flow from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close unless a separate check valve is added if reverse free flow is required in the circuit. For superior dynamic response, direct-acting valves are recommended as pilot-operated valves like this one are not fast-acting. The PVDALEV can be adjusted throughout its full range using W or Y controls unless specified otherwise with a special setting representing the maximum setting of the valve. It also features a cavity T-21A series with a capacity of 10 gpm (40 L/min) and comes equipped with Viton seals for durability in various applications.
The Sun Hydraulics PVDALEV (Material Number: PVDALEV) is an externally drained, pilot-operated pressure reducing and relieving valve designed to maintain a constant reduced pressure at port 1 from a high primary pressure at inlet port 2, while offering a full-flow relief function to tank port 3. This valve is insensitive to pressure at tank port 3 due to its external pilot section drainage at port 4, allowing for remote control by pilot or two-way valves. With a maximum operating pressure of 5000 psi (350 bar), the PVDALEV exhibits low deadband transition between reducing and relieving modes and features exceptionally flat pressure-flow characteristics for stability and low hysteresis. The valve's design incorporates Sun\u2019s floating style construction to minimize internal binding due to installation torque or machining variations. The recommended maximum inlet pressure varies with the adjustment range, tested with differentials of up to 5000 psi (350 bar) for ranges C and W. The valve allows reverse flow from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close unless a separate check valve is added if reverse free flow is required in the circuit. For superior dynamic response, direct-acting valves are recommended as pilot-operated valves like this one are not fast-acting. The PVDALEV can be adjusted throughout its full range using W or Y controls unless specified otherwise with a special setting representing the maximum setting of the valve. It also features a cavity T-21A series with a capacity of 10 gpm (40 L/min) and comes equipped with Viton seals for durability in various applications.
Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pressure at port 4 should not exceed 5000 psi (350 bar).
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-21A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-021-006 |
Show FAQ
Additional Resources
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Reducing and Reducing/Relieving Valves
- Manufacturing Sun Cartridge Cavities
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure