You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PVDDLBV


$125.69 USD
  • SUN HYDRAULICS
  • Material:PVDDLBV
  • Model:PVDD-LBV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVDDLBV (Material Number: PVDDLBV) is a ventable, pilot-operated pressure reducing-relieving valve designed to manage high primary pressure at the inlet and maintain a consistent reduced pressure at port 1. It features a full-flow relief function that directs from port 1 to tank port 3. The vent port, port 4, allows for remote control via pilot or two-way valves. This model incorporates a main stage orifice drilled directly into the piston, enhancing durability for physically demanding applications. The valve setting is directly affected by the pressure at port 3 in a 1:1 ratio, with a maximum allowable pressure of 3000 psi (210 bar). The valve is capable of full reverse flow from reduced pressure port 1 to inlet port 2; however, this may cause the main spool to close, necessitating an additional check valve if reverse free flow is required. The PVDDLBV offers low deadband transition between reducing and relieving modes and maintains stability with exceptionally flat pressure-flow characteristics and low hysteresis. It supports maximum inlet pressures based on adjustment ranges: Ranges D, E, N, and Q are tested up to a differential of 2000 psi (140 bar), while ranges A, B, and H support up to 3000 psi (210 bar) differential. For ranges C and W, it can handle up to 5000 psi (350 bar) inlet pressure. The effective valve setting can be adjusted below the nominal setting by controlling the vent port's pressure. The design includes Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. With a capacity of 10 gpm (40 L/min), this model is reliable for various hydraulic applications requiring precise control over system pressures.

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-021-006

Show FAQ

Additional Resources