SUN HYDRAULICS
PVDDLQV
$127.68 USD
- SUN HYDRAULICS
- Material:PVDDLQV
- Model:PVDD-LQV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVDDLQV (Material Number: PVDDLQV) is a ventable, pilot-operated pressure reducing-relieving valve designed to manage high primary pressures, reducing them to a consistent lower pressure at port 1. It features a full-flow relief function from port 1 to the tank at port 3, while the vent port (port 4) allows for remote control via pilot or two-way valves. This valve is engineered with the main stage orifice drilled directly into the piston, enhancing its durability in demanding applications. The pressure at port 3 adds directly to the valve setting at a 1:1 ratio, with a maximum limit of 3000 psi (210 bar). Full reverse flow from reduced pressure port 1 to inlet port 2 may close the main spool; thus, incorporating a separate check valve is advisable if reverse free flow is necessary. The valve demonstrates low deadband transition between reducing and relieving modes and has exceptionally flat pressure-flow characteristics with low hysteresis. It supports control of effective settings below nominal values by adjusting the vent port pressure. The Sun floating style construction minimizes internal binding due to excessive torque or machining variations. Specifications include a cavity T-21A series with a capacity of 10 gpm (40 L/min), maximum operating pressure of 5000 psi (350 bar), and control pilot flow between 7-10 in\u00b3/min (0.11-0.16 L/min). Installation requires a torque of 30-35 lbf ft (41-47 Nm), with adjustments made using an internal hex size of 5/32 inches (4 mm) and locknut torque set between 80-90 lbf in (9-10 Nm). The model weighs approximately .30 lb (.15 kg) and utilizes Viton seal kits for cartridge sealing.
The Sun Hydraulics PVDDLQV (Material Number: PVDDLQV) is a ventable, pilot-operated pressure reducing-relieving valve designed to manage high primary pressures, reducing them to a consistent lower pressure at port 1. It features a full-flow relief function from port 1 to the tank at port 3, while the vent port (port 4) allows for remote control via pilot or two-way valves. This valve is engineered with the main stage orifice drilled directly into the piston, enhancing its durability in demanding applications. The pressure at port 3 adds directly to the valve setting at a 1:1 ratio, with a maximum limit of 3000 psi (210 bar). Full reverse flow from reduced pressure port 1 to inlet port 2 may close the main spool; thus, incorporating a separate check valve is advisable if reverse free flow is necessary. The valve demonstrates low deadband transition between reducing and relieving modes and has exceptionally flat pressure-flow characteristics with low hysteresis. It supports control of effective settings below nominal values by adjusting the vent port pressure. The Sun floating style construction minimizes internal binding due to excessive torque or machining variations. Specifications include a cavity T-21A series with a capacity of 10 gpm (40 L/min), maximum operating pressure of 5000 psi (350 bar), and control pilot flow between 7-10 in\u00b3/min (0.11-0.16 L/min). Installation requires a torque of 30-35 lbf ft (41-47 Nm), with adjustments made using an internal hex size of 5/32 inches (4 mm) and locknut torque set between 80-90 lbf in (9-10 Nm). The model weighs approximately .30 lb (.15 kg) and utilizes Viton seal kits for cartridge sealing.
Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-21A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-021-006 |
Show FAQ
Additional Resources
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Reducing and Reducing/Relieving Valves
- Manufacturing Sun Cartridge Cavities
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction