***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVFBCHN (PVFBCHN) is a ventable, pilot-operated pressure reducing/relieving valve designed to reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with full-flow relief capabilities from port 1 to tank port 3. The vent port (port 4) allows for remote control via pilot or 2-way valves. This valve features low deadband transition between reducing and relieving modes, ensuring smooth operation. The recommended maximum inlet pressure is determined by the adjustment range, with specific ranges tested under varying maximum differential pressures: Ranges D, E, N, and Q up to 2000 psi (140 bar), Ranges A, B, and H up to 3000 psi (210 bar), and Ranges C and W up to 5000 psi (350 bar). The PVFBCHN demonstrates exceptionally flat pressure-flow characteristics with high stability and low hysteresis. It incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. The valve supports full reverse flow from reduced pressure port 1 to inlet port 2 but may require an additional check valve for circuits requiring reverse free flow. By manipulating the vent port's pressure, users can adjust the effective setting of the valve below its nominal setting. With a cavity T-22A series-2 capacity of 20 gpm (80 L/min) and factory pressure settings established at blocked control ports, this model handles a maximum operating pressure of 5000 psi (350 bar). Its construction includes a control pilot flow rate of 10-15 in\u00b3/min (0.16-0.25 L/min), with adjustment facilitated by clockwise turns up to five-and-a-half times for increased settings. Installation specifications include a valve hex size of 1-1/8 inches (28.6 mm) and required installation torque between 45-50 lbf\u00b7ft (61-68 Nm).

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-22A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.70 lb0,30 kg
Seal kit - CartridgeViton: 990-022-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure