SUN HYDRAULICS
PVFBKEV
$198.76 USD
- SUN HYDRAULICS
- Material:PVFBKEV
- Model:PVFB-KEV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVFBKEV (Material Number: PVFBKEV) is a ventable, pilot-operated pressure reducing/relieving valve designed to reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve includes a vent port (port 4) that allows for remote control by pilot or 2-way valves. The pressure at port 3 directly adds to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). The valve features low deadband transition between reducing and relieving modes, ensuring minimal delay in switching functions. It is designed with exceptionally flat pressure-flow characteristics, offering high stability and low hysteresis. The recommended maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar) between inlet and reduced pressure; ranges A, B, and H allow for a maximum differential of 3000 psi (210 bar); ranges C and W can handle up to an inlet pressure of 5000 psi (350 bar). Full reverse flow from reduced pressure port 1 to inlet port 2 may cause the main spool to close, so adding a separate check valve is recommended if reverse free flow is needed. The PVFBKEV incorporates Sun\u2019s floating style construction to minimize internal part binding due to excessive installation torque or cavity/cartridge machining variations. It has an operating capacity of up to 20 gpm (80 L/min), with factory-set pressures established at blocked control ports. The valve's installation torque ranges from 45-50 lbf ft (61-68 Nm), with adjustments made via an internal hex screw. This model weighs approximately .70 lb (.30 kg) and is sealed with Viton material for durability in various applications.
The Sun Hydraulics PVFBKEV (Material Number: PVFBKEV) is a ventable, pilot-operated pressure reducing/relieving valve designed to reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve includes a vent port (port 4) that allows for remote control by pilot or 2-way valves. The pressure at port 3 directly adds to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). The valve features low deadband transition between reducing and relieving modes, ensuring minimal delay in switching functions. It is designed with exceptionally flat pressure-flow characteristics, offering high stability and low hysteresis. The recommended maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar) between inlet and reduced pressure; ranges A, B, and H allow for a maximum differential of 3000 psi (210 bar); ranges C and W can handle up to an inlet pressure of 5000 psi (350 bar). Full reverse flow from reduced pressure port 1 to inlet port 2 may cause the main spool to close, so adding a separate check valve is recommended if reverse free flow is needed. The PVFBKEV incorporates Sun\u2019s floating style construction to minimize internal part binding due to excessive installation torque or cavity/cartridge machining variations. It has an operating capacity of up to 20 gpm (80 L/min), with factory-set pressures established at blocked control ports. The valve's installation torque ranges from 45-50 lbf ft (61-68 Nm), with adjustments made via an internal hex screw. This model weighs approximately .70 lb (.30 kg) and is sealed with Viton material for durability in various applications.
Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-22A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .70 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-022-006 |
Show FAQ
Additional Resources
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Reducing and Reducing/Relieving Valves
- Manufacturing Sun Cartridge Cavities
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure