SUN HYDRAULICS
PVFDCEV
$201.24 USD
- SUN HYDRAULICS
- Material:PVFDCEV
- Model:PVFD-CEV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVFDCEV (PVFDCEV) is a versatile ventable, pilot-operated pressure reducing/relieving valve designed to maintain a constant reduced pressure at port 1 while providing a full-flow relief function from port 1 to tank port 3. This valve is engineered with the main stage orifice drilled directly into the piston, enhancing its durability for demanding applications. The vent port (port 4) allows for remote control by pilot or two-way valves, offering additional flexibility in system design. The pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). For scenarios requiring reverse flow from reduced pressure port 1 to inlet port 2, it is advisable to incorporate a separate check valve in the circuit as the main spool may close. The PVFDCEV demonstrates low deadband transition between reducing and relieving modes and maintains exceptionally flat pressure-flow characteristics with high stability and low hysteresis. It supports various adjustment ranges, with maximum inlet pressures determined by these ranges, such as up to 5000 psi (350 bar) for ranges C and W. By controlling the vent port pressure, users can adjust the effective setting below nominal levels. The valve's floating style construction minimizes potential binding issues due to installation torque or cavity machining variations. It fits into a T-22A cavity and has a capacity of up to 20 gpm (80 L/min). Factory pressure settings are established with blocked control ports, and it operates at a maximum of 5000 psi (350 bar). The control pilot flow ranges from 10-15 in\u00b3/min (0.16-0.25 L/min), with adjustment facilitated by an internal hex screw and locknut for secure settings maintenance.
The Sun Hydraulics PVFDCEV (PVFDCEV) is a versatile ventable, pilot-operated pressure reducing/relieving valve designed to maintain a constant reduced pressure at port 1 while providing a full-flow relief function from port 1 to tank port 3. This valve is engineered with the main stage orifice drilled directly into the piston, enhancing its durability for demanding applications. The vent port (port 4) allows for remote control by pilot or two-way valves, offering additional flexibility in system design. The pressure at port 3 adds directly to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar). For scenarios requiring reverse flow from reduced pressure port 1 to inlet port 2, it is advisable to incorporate a separate check valve in the circuit as the main spool may close. The PVFDCEV demonstrates low deadband transition between reducing and relieving modes and maintains exceptionally flat pressure-flow characteristics with high stability and low hysteresis. It supports various adjustment ranges, with maximum inlet pressures determined by these ranges, such as up to 5000 psi (350 bar) for ranges C and W. By controlling the vent port pressure, users can adjust the effective setting below nominal levels. The valve's floating style construction minimizes potential binding issues due to installation torque or cavity machining variations. It fits into a T-22A cavity and has a capacity of up to 20 gpm (80 L/min). Factory pressure settings are established with blocked control ports, and it operates at a maximum of 5000 psi (350 bar). The control pilot flow ranges from 10-15 in\u00b3/min (0.16-0.25 L/min), with adjustment facilitated by an internal hex screw and locknut for secure settings maintenance.
Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.
- These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-22A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 10 - 15 in³/min.0,16 - 0,25 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .70 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-022-006 |
Show FAQ
Additional Resources
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Reducing and Reducing/Relieving Valves
- Manufacturing Sun Cartridge Cavities
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction