You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PVFDKEV


$207.20 USD
  • SUN HYDRAULICS
  • Material:PVFDKEV
  • Model:PVFD-KEV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVFDKEV (PVFDKEV) is a ventable, pilot-operated pressure reducing-relieving valve designed to maintain a constant reduced pressure at port 1 while allowing full-flow relief from port 1 to tank port 3. This valve is particularly robust due to the main stage orifice being drilled directly into the piston, making it suitable for demanding applications. The vent port (port 4) offers remote control capabilities via pilot or two-way valves. Pressure at port 3 adds directly to the valve setting in a 1:1 ratio, not exceeding 3000 psi (210 bar). The valve supports reverse flow from reduced pressure port 1 to inlet port 2, though this may close the main spool; therefore, a separate check valve is recommended if reverse free flow is needed. Pilot-operated valves like this one exhibit low deadband transition between reducing and relieving modes and are known for their stability and low hysteresis. The maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q support up to a 2000 psi (140 bar) differential, while ranges A, B, and H allow up to a 3000 psi (210 bar) differential. Ranges C and W accommodate up to 5000 psi (350 bar). This model incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. Specifications include a capacity of 20 gpm (80 L/min), maximum operating pressure of 5000 psi (350 bar), control pilot flow of 10-15 in\u00b3/min (.16-.25 L/min), with adjustments made via an internal hex screw. The PVFDKEV weighs .70 lb (.30 kg), featuring Viton seals for durability and compatibility with various fluids.

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-22A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.70 lb0,30 kg
Seal kit - CartridgeViton: 990-022-006

Show FAQ

Additional Resources