You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PVFDKWN


$196.28 USD
  • SUN HYDRAULICS
  • Material:PVFDKWN
  • Model:PVFD-KWN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVFDKWN (PVFDKWN) is a ventable, pilot-operated pressure reducing/relieving valve designed to maintain a constant reduced pressure at port 1 from a higher primary pressure at the inlet, while providing a full-flow relief function from port 1 to tank port 3. The valve features a vent port (port 4) that enables remote control via pilot or 2-way valves. Its design incorporates the main stage orifice drilled directly into the piston, enhancing durability in physically demanding applications. The valve allows for direct additive pressure at port 3 relative to the valve setting at a 1:1 ratio, with a maximum limit of 3000 psi (210 bar). It can handle reverse flow from reduced pressure port 1 to inlet port 2, though this may cause the main spool to close. If reverse free flow is required, adding a separate check valve is recommended. This pilot-operated valve offers low deadband transitions between reducing and relieving modes and exhibits exceptionally flat pressure-flow characteristics with high stability and low hysteresis. The maximum recommended inlet pressure varies by adjustment range: Ranges D, E, N, and Q are tested with up to a 2000 psi (140 bar) differential; Ranges A, B, and H with up to a 3000 psi (210 bar) differential; Ranges C and W can handle up to 5000 psi (350 bar). The effective setting can be adjusted below nominal by controlling the vent port's pressure. It features Sun's floating style construction to minimize internal binding due to excessive installation torque or machining variations in cavity/cartridge setups. The PVFDKWN has a capacity of 20 gpm (80 L/min), operates at pressures up to 5000 psi (350 bar), and includes specific installation torque requirements for optimal performance.

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-22A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.70 lb0,30 kg
Seal kit - CartridgeViton: 990-022-006

Show FAQ