You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PVJCCEV


$812.41 USD
  • SUN HYDRAULICS
  • Material:PVJCCEV
  • Model:PVJC-CEV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVJCCEV (PVJCCEV) is an externally drained, pilot-operated pressure reducing/relieving valve designed to maintain a constant reduced pressure at port 1 from a higher primary pressure at inlet port 2. This model features a full-flow relief function from port 1 to tank port 3, making it insensitive to pressure at tank port 3 due to its pilot section draining at port 4. The valve is capable of remote control via pilot or two-way valves and is constructed with Sun's floating style design to prevent internal part binding due to excessive installation torque or machining variations. The PVJCCEV can handle a maximum operating pressure of up to 5000 psi (350 bar) and offers exceptionally stable performance with low hysteresis, thanks to its flat pressure-flow characteristics. It is important to note that this pilot-operated valve exhibits low deadband transition between reducing and relieving modes but is not as fast-acting as direct-acting valves, which should be considered for applications requiring superior dynamic response. This model has specific recommended maximum inlet pressures based on the adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while ranges A, B, and H allow for up to 3000 psi (210 bar). For ranges C and W, the inlet pressure can reach up to 5000 psi (350 bar). The effective setting of the valve can be increased by controlling the pressure at drain port 4; however, this should not exceed 5000 psi (350 bar). With a capacity of up to 80 gpm (320 L/min), this valve ensures reliable performance in maintaining desired system pressures while preventing overpressure conditions in secondary circuits. Its robust design includes features like a locknut hex size of 9/16 in. (15 mm) and an adjustment screw internal hex size of 5/32 in. (4 mm), ensuring ease of use and precise adjustments.

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-24A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-024-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure