SUN HYDRAULICS
PVJCCJN


$804.47 USD
  • SUN HYDRAULICS
  • Material:PVJCCJN
  • Model:PVJC-CJN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVJCCJN (PVJCCJN) is an externally drained, pilot-operated pressure reducing/relieving valve designed to maintain a consistent reduced pressure from a high primary pressure at the inlet port 2 to port 1, while offering full-flow relief from port 1 to tank port 3. This valve is insensitive to pressure at tank port 3 due to its external draining feature at port 4, allowing for remote control via pilot or two-way valves. The maximum allowable pressure at tank port 3 is capped at 3000 psi (210 bar). The valve showcases a low deadband transition between reducing and relieving modes, with exceptionally flat pressure-flow characteristics that ensure stability and low hysteresis. It accommodates various pressure ranges, with Ranges D, E, N, and Q supporting a maximum differential of 2000 psi (140 bar), while Ranges A, B, and H support up to 3000 psi (210 bar), and Ranges C and W can handle up to 5000 psi (350 bar). The valve's drain port pressure is directly additive to the valve setting in a 1:1 ratio but should not surpass 5000 psi (350 bar). Notably, pilot-operated valves like this one are not fast-acting; for enhanced dynamic response, direct-acting valves are recommended. By adjusting the drain port's pressure, the effective setting of the valve can be increased beyond its nominal setting. The PVJCCJN incorporates Sun's floating style construction to minimize binding risks due to installation torque or machining variations. It fits into Cavity T-24A with Series 4 capacity of up to 80 gpm (320 L/min) and operates under a maximum pressure of 5000 psi (350 bar), with factory settings established at blocked control ports.

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-24A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-024-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure