SUN HYDRAULICS
PVJCKCV
$819.36 USD
- SUN HYDRAULICS
- Material:PVJCKCV
- Model:PVJC-KCV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVJCKCV (PVJCKCV) is an externally drained, pilot-operated pressure reducing/relieving valve designed to manage high primary pressure at inlet port 2, reducing it to a consistent lower pressure at port 1 while providing full-flow relief from port 1 to tank port 3. This valve is engineered for stability and low hysteresis, featuring exceptionally flat pressure-flow characteristics. It allows for remote control via pilot or two-way valves by draining the pilot section at port 4, rendering it insensitive to tank port 3 pressures. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar), and the recommended maximum inlet pressure varies by adjustment range: Ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while A, B, and H can handle up to a 3000 psi (210 bar) differential. Ranges C and W are suitable for inlet pressures up to 5000 psi (350 bar). The valve's design incorporates Sun's floating style construction to minimize internal part binding due to installation torque or machining variations. It operates with a control pilot flow of 15-20 in\u00b3/min (0.25-0.33 L/min) and can be adjusted using a screw with an internal hex size of 5/32 in. The PVJCKCV model weighs approximately 3.10 lb (1.40 kg) and requires specific installation torque settings for optimal performance: valve installation torque is between 350-375 lbf\u00b7ft (474-508 Nm), while the locknut torque ranges from 80-90 lbf\u00b7in (9-10 Nm). This valve is not intended for fast-acting applications; users seeking superior dynamic response should consider direct acting valves instead.
The Sun Hydraulics PVJCKCV (PVJCKCV) is an externally drained, pilot-operated pressure reducing/relieving valve designed to manage high primary pressure at inlet port 2, reducing it to a consistent lower pressure at port 1 while providing full-flow relief from port 1 to tank port 3. This valve is engineered for stability and low hysteresis, featuring exceptionally flat pressure-flow characteristics. It allows for remote control via pilot or two-way valves by draining the pilot section at port 4, rendering it insensitive to tank port 3 pressures. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar), and the recommended maximum inlet pressure varies by adjustment range: Ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while A, B, and H can handle up to a 3000 psi (210 bar) differential. Ranges C and W are suitable for inlet pressures up to 5000 psi (350 bar). The valve's design incorporates Sun's floating style construction to minimize internal part binding due to installation torque or machining variations. It operates with a control pilot flow of 15-20 in\u00b3/min (0.25-0.33 L/min) and can be adjusted using a screw with an internal hex size of 5/32 in. The PVJCKCV model weighs approximately 3.10 lb (1.40 kg) and requires specific installation torque settings for optimal performance: valve installation torque is between 350-375 lbf\u00b7ft (474-508 Nm), while the locknut torque ranges from 80-90 lbf\u00b7in (9-10 Nm). This valve is not intended for fast-acting applications; users seeking superior dynamic response should consider direct acting valves instead.
Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-24A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 3.10 lb1,40 kg |
| Seal kit - Cartridge | Viton: 990-024-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure