SUN HYDRAULICS
PVJCLDV
$804.47 USD
- SUN HYDRAULICS
- Material:PVJCLDV
- Model:PVJC-LDV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVJCLDV (PVJCLDV) is an externally drained, pilot-operated pressure reducing/relieving valve designed to manage high primary pressure at inlet port 2, converting it to a consistent reduced pressure at port 1, while also providing a full-flow relief function from port 1 to tank port 3. This valve features a pilot section drainage at port 4, making it insensitive to tank port 3 pressure and allowing remote control via pilot or two-way valves. It functions with a maximum pressure limit of 3000 psi (210 bar) at port 3. The design ensures low deadband transition between reducing and relieving modes and exhibits exceptionally flat pressure-flow characteristics with low hysteresis, contributing to its stability. The valve's recommended maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while ranges A, B, and H accommodate up to 3000 psi (210 bar), and ranges C and W can handle up to 5000 psi (350 bar). The effective valve setting can be increased by controlling the drain port's pressure at a direct ratio of 1:1 without exceeding 5000 psi (350 bar). Although not fast-acting by nature due to its pilot operation, this valve incorporates Sun's floating style construction to minimize potential internal part binding from excessive installation torque or cavity/cartridge machining variations. With a capacity of handling up to 80 gpm (320 L/min), the PVJCLDV operates under a maximum operating pressure of 5000 psi (350 bar). It requires specific installation torques for optimal performance: valve installation torque is between 350\u2013375 lbf ft (474\u2013508 Nm), with locknut torque ranging from 80\u201390 lbf in. The model weighs approximately 3.10 lb (1.40 kg) and uses Viton seal kits for cartridge sealing.
The Sun Hydraulics PVJCLDV (PVJCLDV) is an externally drained, pilot-operated pressure reducing/relieving valve designed to manage high primary pressure at inlet port 2, converting it to a consistent reduced pressure at port 1, while also providing a full-flow relief function from port 1 to tank port 3. This valve features a pilot section drainage at port 4, making it insensitive to tank port 3 pressure and allowing remote control via pilot or two-way valves. It functions with a maximum pressure limit of 3000 psi (210 bar) at port 3. The design ensures low deadband transition between reducing and relieving modes and exhibits exceptionally flat pressure-flow characteristics with low hysteresis, contributing to its stability. The valve's recommended maximum inlet pressure varies by adjustment range: ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), while ranges A, B, and H accommodate up to 3000 psi (210 bar), and ranges C and W can handle up to 5000 psi (350 bar). The effective valve setting can be increased by controlling the drain port's pressure at a direct ratio of 1:1 without exceeding 5000 psi (350 bar). Although not fast-acting by nature due to its pilot operation, this valve incorporates Sun's floating style construction to minimize potential internal part binding from excessive installation torque or cavity/cartridge machining variations. With a capacity of handling up to 80 gpm (320 L/min), the PVJCLDV operates under a maximum operating pressure of 5000 psi (350 bar). It requires specific installation torques for optimal performance: valve installation torque is between 350\u2013375 lbf ft (474\u2013508 Nm), with locknut torque ranging from 80\u201390 lbf in. The model weighs approximately 3.10 lb (1.40 kg) and uses Viton seal kits for cartridge sealing.
Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-24A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 3.10 lb1,40 kg |
| Seal kit - Cartridge | Viton: 990-024-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure