You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
QCDCKBN


$188.53 USD
  • SUN HYDRAULICS
  • Material:QCDCKBN
  • Model:QCDC-KBN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics QCDCKBN (Material Number: QCDCKBN) is an accumulator sense, pump unload pilot valve designed to optimize hydraulic systems by managing pressure efficiently. This valve senses pressure in an accumulator at port 2, and upon reaching the preset valve setting, it connects port 3 to port 4 to vent a relief valve and unload the pump. A notable feature is its 30:1 ratio between unload setting and reset; when pressure at port 2 drops below 70% of the valve setting, port 3 is blocked from port 4, allowing the pump to recharge the accumulator. The integral free-flow check valve supports pump flows up to 12 gpm (50 L/min). For higher capacity pumps, another variant known as QPAC is available that requires a separate check cartridge. The QCDCKBN maintains a precise differential ratio due to its spool design, which ensures consistent performance by using fixed diameters that resist wear. To mitigate potential silting issues, it has minimal clearances between the spool and sleeve along with a seal on the pilot piston diameter. A separate drain line is necessary during application to avoid erratic operation from tank line pressure fluctuations. Users must select an appropriate adjustment range carefully since system pressure drops and flow rates can impact unloading valves' operation significantly. This model fits into a T-21A cavity with a series 1 capacity of up to 15 gpm (60 L/min) and can withstand maximum operating pressures of up to 5000 psi (350 bar). It features a check cracking pressure of 4 psi (0.3 bar) and offers various adjustment options for precise control. The cartridge's construction includes Sun's floating style design, minimizing internal binding risks due to installation torque or machining variations.

The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 2 of the valve and when the pressure at port 2 reaches the valve setting, port 3 connects to port 4 to vent a relief valve and unload the pump. This valve has a 30% ratio between unload setting and reset; when pressure at port 2 falls below 70% of the valve setting, port 3 is blocked from port 4 and the pump will come back online to recharge the accumulator. The integral free-flow check valve is suitable for pump flows up to 12 gpm (50 L/min). For higher capacity pumps, another version of accumulator sense, pump unload cartridge, QPAC, which requires a separate check cartridge is available.

  • The pressure differential between unload and reset will be within +/- 1% of the stated ratio of the valve with up to an additional 25 psi (1,7 bar) due to dynamic seal friction.
  • The accumulator sensing area is positively sealed.
  • The spool design of this valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • Minimum clearances between the spool and sleeve and a seal on the pilot piston diameter significantly reduce the potential for silting.
  • When applying this cartridge, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • Sun has designed a variety of standard accumulator/pump unload assemblies with a variety of features. These assemblies can be found on our website under SOLUTIONS: ACCUMLATOR SENSE, PUMP UNLOAD.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity15 gpm60 L/min.
Maximum Operating Pressure5000 psi350 bar
Check Cracking Pressure4 psi0,3 bar
Pressure Drop, Port 1 to Port 2100 psi@15 gpm7 bar@60 L/min.
Pilot Flow Capacity46 in³/min.0,75 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.35 lb0,15 kg
Seal kit - CartridgeViton: 990-021-006

Show FAQ

Additional Resources