***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics QPABCDV (Material Number: QPABCDV) is an accumulator sense, pump unload pilot valve designed to optimize hydraulic system performance by sensing pressure in an accumulator at port 1. When the pressure at port 1 reaches the valve setting, the valve connects port 2 to port 3, venting a relief valve and unloading the pump. This mechanism allows for efficient energy management within hydraulic systems. The valve features a fixed differential ratio with a 20:1 unload to reset setting, ensuring that when pressure falls below 80% of the set value, port 2 is blocked from port 3, and the pump recharges the accumulator. A separate check valve between port 1 and the pump is necessary for proper operation. The QPABCDV's spool design maintains consistent performance by using diameters on the spool that resist wear over time. It reduces potential silting through minimal clearances between spool and sleeve and incorporates a seal on the pilot piston diameter. A separate drain line is required to prevent erratic behavior caused by tank line pressure fluctuations. Users should carefully select adjustment ranges due to system pressure drops and flows affecting unloading valve operations; low operating pressures combined with low differentials result in narrow bands between unload and reset settings. This model has a cavity T-11A, Series 1 capacity of .46 in\u00b3/min (0.75 L/min) and operates at a maximum pressure of 5000 psi (350 bar). Installation requires precise torque settings\u201430 to 35 lbf\u00b7ft (41 to 47 Nm)\u2014and adjustments are made via an internal hex screw. The QPABCDV incorporates Sun's floating style construction to minimize internal part binding due to installation torque or machining variations, promoting reliable long-term use in hydraulic applications.

The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 1 of the valve and when the pressure at port 1 reaches the valve setting, port 2 connects to port 3 to vent a relief valve and unload the pump. This valve has a 20% ratio between unload setting and reset; when pressure at port 1 falls below 80% of the valve setting, port 2 is blocked from port 3 and the pump will come back online to recharge the accumulator. This valve requires a separate check valve between port 1 and the pump. Another version of the accumulator sense, pump unload valve, QCDB, includes a free-flow check valve for pump flows under 12 gpm (50 L/min).

  • The pressure differential between unload and reset will be within +/- 1% of the stated ratio of the valve with up to an additional 25 psi (1,7 bar) due to dynamic seal friction.
  • The accumulator sensing area is positively sealed.
  • The spool design of this valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • Minimum clearances between the spool and sleeve and a seal on the pilot piston diameter significantly reduce the potential for silting.
  • When applying this cartridge, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • Sun has designed a variety of standard accumulator/pump unload assemblies with a variety of features. These assemblies can be found on our website under SOLUTIONS: ACCUMLATOR SENSE, PUMP UNLOAD.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity46 in³/min.0,75 L/min.
Maximum Operating Pressure5000 psi350 bar
Pilot Flow Capacity46 in³/min.0,75 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.35 lb0,15 kg