SUN HYDRAULICS
QPABKDN
$183.87 USD
- SUN HYDRAULICS
- Material:QPABKDN
- Model:QPAB-KDN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics QPABKDN (Material Number: QPABKDN) is an accumulator sense, pump unload pilot valve designed to optimize hydraulic systems by managing pressure levels efficiently. This valve senses pressure in an accumulator at port 1 and, when the set pressure is reached, connects port 2 to port 3, venting a relief valve and unloading the pump. It features a 20:1 ratio between unload setting and reset; once the pressure at port 1 falls below 80% of the set value, port 2 is blocked from port 3, allowing the pump to recharge the accumulator. A separate check valve is required between port 1 and the pump for optimal operation. The valve maintains a fixed differential ratio thanks to its spool design, minimizing wear over time. Its construction ensures minimal silting through precise spool-to-sleeve clearances and a sealed pilot piston diameter. For consistent performance, a separate drain line is necessary to mitigate erratic behavior due to tank line pressure fluctuations. When choosing an adjustment range, it\u2019s crucial to consider system pressure drops and flows as they affect unloading valves' operation; low pressures combined with low differentials require precise system design. This model incorporates Sun's floating style construction to reduce binding risks due to installation torque or machining variations. It fits into Cavity T-11A Series 1 with a capacity of 46 in\u00b3/min (0.75 L/min) and can withstand maximum operating pressures of up to 5000 psi (350 bar). The adjustment requires five clockwise turns for increased setting, with specific torque requirements for installation and adjustments provided for precision handling.
The Sun Hydraulics QPABKDN (Material Number: QPABKDN) is an accumulator sense, pump unload pilot valve designed to optimize hydraulic systems by managing pressure levels efficiently. This valve senses pressure in an accumulator at port 1 and, when the set pressure is reached, connects port 2 to port 3, venting a relief valve and unloading the pump. It features a 20:1 ratio between unload setting and reset; once the pressure at port 1 falls below 80% of the set value, port 2 is blocked from port 3, allowing the pump to recharge the accumulator. A separate check valve is required between port 1 and the pump for optimal operation. The valve maintains a fixed differential ratio thanks to its spool design, minimizing wear over time. Its construction ensures minimal silting through precise spool-to-sleeve clearances and a sealed pilot piston diameter. For consistent performance, a separate drain line is necessary to mitigate erratic behavior due to tank line pressure fluctuations. When choosing an adjustment range, it\u2019s crucial to consider system pressure drops and flows as they affect unloading valves' operation; low pressures combined with low differentials require precise system design. This model incorporates Sun's floating style construction to reduce binding risks due to installation torque or machining variations. It fits into Cavity T-11A Series 1 with a capacity of 46 in\u00b3/min (0.75 L/min) and can withstand maximum operating pressures of up to 5000 psi (350 bar). The adjustment requires five clockwise turns for increased setting, with specific torque requirements for installation and adjustments provided for precision handling.
The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 1 of the valve and when the pressure at port 1 reaches the valve setting, port 2 connects to port 3 to vent a relief valve and unload the pump. This valve has a 20% ratio between unload setting and reset; when pressure at port 1 falls below 80% of the valve setting, port 2 is blocked from port 3 and the pump will come back online to recharge the accumulator. This valve requires a separate check valve between port 1 and the pump. Another version of the accumulator sense, pump unload valve, QCDB, includes a free-flow check valve for pump flows under 12 gpm (50 L/min).
- The pressure differential between unload and reset will be within +/- 1% of the stated ratio of the valve with up to an additional 25 psi (1,7 bar) due to dynamic seal friction.
- The accumulator sensing area is positively sealed.
- The spool design of this valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- Minimum clearances between the spool and sleeve and a seal on the pilot piston diameter significantly reduce the potential for silting.
- When applying this cartridge, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- Sun has designed a variety of standard accumulator/pump unload assemblies with a variety of features. These assemblies can be found on our website under SOLUTIONS: ACCUMLATOR SENSE, PUMP UNLOAD.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 46 in³/min.0,75 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Pilot Flow Capacity | 46 in³/min.0,75 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .35 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- CavitySaver multi-function valves deliver single-cartridge solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Accumulator Sense, Pump Unload Valves
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Manufacturing Sun Cartridge Cavities
- Circuit Savers
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Performance Data
- Sun Model Code Explanation; 999-901-334
- Units of Measure, Settings, and Conversions
- Cartridges: Materials of Construction
- Cavity Information (S-171) and Tooling