***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics QPACCCV (Material Number: QPACCCV) is an accumulator sense, pump unload pilot valve designed to monitor and manage pressure in hydraulic systems. This valve operates by sensing pressure at port 1 of the valve; when the pressure reaches a predetermined setting, it connects port 2 to port 3, venting a relief valve and unloading the pump. The QPACCCV features a 30:1 ratio between unload setting and reset, meaning when the pressure at port 1 falls below 70% of the set value, port 2 is blocked from port 3, allowing the pump to recharge the accumulator. It requires a separate check valve between port 1 and the pump for optimal operation. The design incorporates a positively sealed accumulator sensing area and utilizes a spool design that maintains a fixed differential ratio. This is achieved through diameters on the spool that resist wear over time. The minimal clearances between spool and sleeve, along with a seal on the pilot piston diameter, help reduce potential silting issues. For effective application, a separate drain line is necessary to prevent erratic operations due to tank line pressure fluctuations. This cartridge valve fits into Cavity T-11A with Series 1 capacity specifications of up to 46 in\u00b3/min (0.75 L/min) and can withstand maximum operating pressures of up to 5000 psi (350 bar). The adjustment requires up to five clockwise turns to increase settings with specific installation torques for both the valve and locknut components. The use of Sun's floating style construction minimizes risks of internal part binding from excessive installation torque or machining variations in cavity/cartridge setups, ensuring reliable performance in demanding environments.

The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 1 of the valve and when the pressure at port 1 reaches the valve setting, port 2 connects to port 3 to vent a relief valve and unload the pump. This valve has a 30% ratio between unload setting and reset; when pressure at port 1 falls below 70% of the valve setting, port 2 is blocked from port 3 and the pump will come back online to recharge the accumulator. This valve requires a separate check valve between port 1 and the pump. Another version of the accumulator sense, pump unload valve, QCDC, includes a free-flow check valve for pump flows under 12 gpm (50 L/min).

  • The pressure differential between unload and reset will be within +/- 1% of the stated ratio of the valve with up to an additional 25 psi (1,7 bar) due to dynamic seal friction.
  • The accumulator sensing area is positively sealed.
  • The spool design of this valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • Minimum clearances between the spool and sleeve and a seal on the pilot piston diameter significantly reduce the potential for silting.
  • When applying this cartridge, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • Sun has designed a variety of standard accumulator/pump unload assemblies with a variety of features. These assemblies can be found on our website under SOLUTIONS: ACCUMLATOR SENSE, PUMP UNLOAD.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity46 in³/min.0,75 L/min.
Maximum Operating Pressure5000 psi350 bar
Pilot Flow Capacity46 in³/min.0,75 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.35 lb0,15 kg