You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
QPADKDV


$191.81 USD
  • SUN HYDRAULICS
  • Material:QPADKDV
  • Model:QPAD-KDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics QPADKDV (Material Number: QPADKDV) is an accumulator sense, pump unload pilot valve designed to efficiently manage pressure in hydraulic systems. This valve senses pressure at port 1 and, upon reaching a predetermined setting, connects port 2 to port 3 to vent a relief valve and unload the pump. It features a 50% ratio between unload setting and reset, allowing the pump to recharge the accumulator when pressure falls below this threshold. For optimal operation, a separate check valve is required between port 1 and the pump. The QPADKDV model is engineered with a spool design that maintains a fixed differential ratio due to its non-wearing diameters, ensuring consistent performance over time. It also incorporates minimum clearances and pilot piston seals to reduce silting risks. The valve's construction includes Sun's floating style design, minimizing internal binding risks due to installation torque or machining variations. It requires a separate drain line to prevent erratic behavior from tank line pressure fluctuations. Users should carefully select the adjustment range as system pressure drops and flow rates can impact the unloading operation; low pressures with low differentials demand precise system design while high flow rates may increase pressure drops affecting differential operations. This model has an operating capacity of 46 in\u00b3/min (0.75 L/min) and supports a maximum operating pressure of 5000 psi (350 bar). Installation requires specific torque settings for both the valve and locknut components, ensuring secure placement within hydraulic systems. The QPADKDV is compatible with Viton seal kits for reliable sealing performance under various conditions.

The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 1 of the valve and when the pressure at port 1 reaches the valve setting, port 2 connects to port 3 to vent a relief valve and unload the pump. This valve has a 50% ratio between unload setting and reset; when pressure at port 1 falls below 50% of the valve setting, port 2 is blocked from port 3 and the pump will come back online to recharge the accumulator. This valve requires a separate check valve between port 1 and the pump. Another version of the accumulator sense, pump unload valve, QCDD, includes a free-flow check valve for pump flows under 12 gpm (50 L/min).

  • The pressure differential between unload and reset will be within +/- 1% of the stated ratio of the valve with up to an additional 25 psi (1,7 bar) due to dynamic seal friction.
  • The accumulator sensing area is positively sealed.
  • The spool design of this valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • Minimum clearances between the spool and sleeve and a seal on the pilot piston diameter significantly reduce the potential for silting.
  • When applying this cartridge, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • Sun has designed a variety of standard accumulator/pump unload assemblies with a variety of features. These assemblies can be found on our website under SOLUTIONS: ACCUMLATOR SENSE, PUMP UNLOAD.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity46 in³/min.0,75 L/min.
Maximum Operating Pressure5000 psi350 bar
Pilot Flow Capacity46 in³/min.0,75 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.35 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources