***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RBACJEN (RBACJEN) is a direct-acting, pilot relief cartridge designed for remote control of pressure settings in pilot-operated valves. This component is ideal for load holding applications and should be paired with higher flow valves due to its capacity being limited to pilot flow. The valve's main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability in operation. It's particularly suitable for systems utilizing phosphate ester fluids, as cartridges with EPDM seals are specifically designed for such use; exposure to petroleum-based fluids can damage these seals. The RBACJEN model features corrosion-resistant options, identifiable by the suffixes AP or LH in the model code, indicating external stainless steel or zinc-nickel plated components, respectively. It incorporates Sun\u2019s floating style construction to prevent internal parts from binding due to excessive installation torque or machining variations. This valve allows back pressure on the tank port (port 2) that directly adds to the valve setting at a 1:1 ratio. For adjustments, it offers W and Y controls that can be specified with or without a special setting. The valve is adjustable throughout its full range unless a special setting is specified, which then represents the maximum setting. The RBACJEN supports a maximum operating pressure of 5000 psi (350 bar) and has a typical response time of 2 ms. It maintains minimal leakage at standard conditions, making it both efficient and reliable for various applications requiring precise pressure control.

Direct-acting, pilot relief cartridges are used to remotely control the pressure setting of other pilot-operated valves. Because capacity is limited to pilot flow, these valves should be used with other higher flow valves.

  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Suitable for use in load holding applications.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-10A
Series1
Capacity.25 gpm1 L/min.
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical2 ms2 ms
Maximum Valve Leakage at 110 SUS (24 cSt)5 drops/min.0,3 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-010-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.