***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RBACYEN (Material Number: RBACYEN) is a direct-acting, pilot relief cartridge designed to remotely control the pressure setting of other pilot-operated valves. This valve is particularly suitable for applications requiring load holding and is effective in systems utilizing phosphate ester fluids, thanks to its EPDM seals. However, it should be noted that exposure to petroleum-based fluids can damage these seals. The main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability. This cartridge valve can handle a maximum operating pressure of 5000 psi (350 bar) and has a capacity of 0.25 gpm (1 L/min). Its response time is typically around 2 milliseconds with minimal leakage at standard conditions. The RBACYEN model incorporates Sun's floating style construction, which helps prevent internal binding due to excessive installation torque or machining variations. It also features corrosion-resistant options identified by specific suffixes in the model code for environments prone to corrosion. Adjustment settings are versatile; the valve can be adjusted throughout its full range using W or Y controls unless a special maximum setting is specified. Installation requires a cavity T-10A with series 1 specifications, and the valve hex size measures 7/8 inch (22.2 mm). Installation torque ranges between 30 to 35 lbf ft (41 to 47 Nm), while the adjustment screw and locknut have specific hex sizes and torque requirements for secure installation. The product weighs approximately 0.30 lb (0.15 kg), making it lightweight yet robust for its intended applications.

Direct-acting, pilot relief cartridges are used to remotely control the pressure setting of other pilot-operated valves. Because capacity is limited to pilot flow, these valves should be used with other higher flow valves.

  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Suitable for use in load holding applications.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-10A
Series1
Capacity.25 gpm1 L/min.
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical2 ms2 ms
Maximum Valve Leakage at 110 SUS (24 cSt)5 drops/min.0,3 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-010-006