You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RBANXAN2D24V


$516.16 USD
  • SUN HYDRAULICS
  • Material:RBANXAN2D24V
  • Model:RBAN-XAN@2D24V
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RBANXAN2D24V (RBANXAN2D24V) is a 2-port, pilot-stage, direct-acting relief cartridge that functions as an electroproportionally controlled, normally closed pressure regulating valve. This valve is spring-biased closed to the highest setting specified by the customer, with pressure adjustments made by varying the current to the coil. As the analog input signal increases, it proportionally decreases the pressure setting. When inlet pressure at port 1 surpasses the combined force of the spring and solenoid (as dictated by the input signal), the poppet lifts to allow flow from port 1 to port 2. The RBANXAN2D24V utilizes a T8A cavity, making it compatible with Sun's main stage pressure control elements and eliminating separate pilot lines for streamlined installation. It offers high pilot capacity for larger main stage elements and features a damped construction for stable operation across various conditions. The valve exhibits low leakage in its closed position with reseat occurring at 85% of cracking pressure. Coils are interchangeable with other Sun solenoid-operated valves and can be mounted in either direction on the tube. For optimal performance, an amplifier with current sensing and adjustable dither (100-250 Hz) is recommended. Proper installation requires first securing the main stage valve followed by torqueing the T8A pilot control section into place. The floating style construction minimizes internal binding risks due to excessive torque or machining variations of cavity/cartridge interfaces. The valve's technical specifications include a maximum operating pressure of 5000 psi (350 bar), maximum valve leakage at reseat of 1.5 in\u00b3/min (.25 cc/min), and a model weight with coil of approximately 1 lb (0.45 kg).

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, normally-closed pressure regulating valve. The valve is spring biased closed to its highest setting (customer specified). Increasing current to the coil will proportionally decrease the pressure setting. When the pressure at port 1 (inlet) is sufficient to overcome the spring force minus the solenoid force, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements.

  • Customer must specify a relief setting that falls within the selected pressure range. This setting represents the maximum relief pressure which the valve will default to with no command. As the command increases, the relief setting will decrease. See performance curves for selected pressure range. This setting is not adjustable in the field.
  • Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
  • This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • High pilot capacity allows for operation of larger size main stage elements.
  • Damped construction provides stable operation over a wide range of operating conditions.
  • Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.)
  • Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-8A
SeriesP
Capacity.25 gpm1 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at Reseat1.5 in³/min.25 cc/min.
Reseat>85% of setting>85% of setting
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque20 - 25 lbf ft27 - 33 Nm
Model Weight (with coil)1.00 lb0,45 kg
Seal kit - CartridgeViton: 990-208-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006

Show FAQ