***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RBANXDV224 (RBANXDV224) is a 2-port, pilot-stage, direct-acting relief cartridge that operates as an electroproportionally controlled, normally closed pressure regulating valve. This valve is designed to be spring-biased closed to the customer's highest specified setting, and it allows for proportional pressure regulation by varying the current to the coil. When the inlet pressure at port 1 surpasses the combined spring force and solenoid force, as determined by an analog input signal, the poppet lifts to permit flow from port 1 to port 2. The RBANXDV224 utilizes the T8A cavity, making it compatible with Sun's main stage pressure control elements. Customers must specify a maximum relief pressure setting within their selected range; this setting is not field-adjustable. The valve provides stepless control of pressure through varying analog input signals and eliminates the need for separate pilot lines by combining control and primary functions in one cavity. It features high pilot capacity for operating larger main stage elements and damped construction for stable operation across various conditions. It ensures low leakage levels when closed, with reseat occurring at 85% of cracking pressure. The interchangeable solenoid coils can be mounted in either direction on the tube for flexibility. For optimal performance, it's recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. Installation involves first correctly torquing the main stage valve followed by securing the T8A pilot control section into it. The floating style construction minimizes risks of internal binding due to excessive torque or machining variations. Key specifications include a maximum operating pressure of 5000 psi (350 bar), a capacity of .25 gpm (1 L/min), and a weight of approximately 1 lb (0.45 kg) with coil included.

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, normally-closed pressure regulating valve. The valve is spring biased closed to its highest setting (customer specified). Increasing current to the coil will proportionally decrease the pressure setting. When the pressure at port 1 (inlet) is sufficient to overcome the spring force minus the solenoid force, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements.

  • Customer must specify a relief setting that falls within the selected pressure range. This setting represents the maximum relief pressure which the valve will default to with no command. As the command increases, the relief setting will decrease. See performance curves for selected pressure range. This setting is not adjustable in the field.
  • Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
  • This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • High pilot capacity allows for operation of larger size main stage elements.
  • Damped construction provides stable operation over a wide range of operating conditions.
  • Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.)
  • Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-8A
SeriesP
Capacity.25 gpm1 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at Reseat1.5 in³/min.25 cc/min.
Reseat>85% of setting>85% of setting
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque20 - 25 lbf ft27 - 33 Nm
Model Weight (with coil)1.00 lb0,45 kg
Seal kit - CartridgeViton: 990-208-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006