You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RQEBFWN


$71.88 USD
  • SUN HYDRAULICS
  • Material:RQEBFWN
  • Model:RQEB-FWN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RQEBFWN (Material Number: RQEBFWN) is a kickdown relief cartridge designed to function similarly to a circuit breaker in hydraulic systems. This valve kicks completely open and remains open once the inlet port 1 pressure exceeds the valve setting, allowing unrestricted flow from port 1 to tank port 2. The valve stays open as long as the pressure at port 1 is greater than at port 2. To reset, flow must cease, and pressure at port 2 must equal or exceed that at port 1. It is not suitable for load holding applications and should be used on the actuator side of a system, as pump flow must stop for resetting if used on the pump side. The main stage orifice is protected by a 150-micron stainless steel screen, enhancing durability in corrosive environments when configured with corrosion-resistant options like AP or LH suffixes for stainless steel or zinc-nickel plating, respectively. This Series-1 cartridge fits into Cavity T-10A and offers a capacity of up to 25 gpm (95 L/min) with a maximum operating pressure of 5000 psi (350 bar). Its response time is typically about 25 ms, and it features minimal leakage rates under specified conditions. The valve's adjustment mechanism allows setting changes with five clockwise turns, while installation requires specific torque values for optimal performance. Weighing only .30 lb (.15 kg), this model employs Sun's floating style construction to avoid internal binding due to excessive torque or machining variations. Common applications include safety mechanisms on devices like portable grain augers, where it prevents equipment damage by tripping when obstructions occur.

Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve settting, creating an unrestricted flow path from port 1 to tank (port 2). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • To reset valve, flow through the cartridge must cease.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications.
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-10A
Series1
Capacity25 gpm95 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-010-006

Show FAQ

Additional Resources



Notes:
  • Do not use in load holding applications.
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.