***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RQEBJBV (RQEBJBV) is a kickdown relief cartridge designed to function similarly to a circuit breaker in an electrical system. This valve activates fully open when the pressure at inlet port 1 surpasses its set threshold, allowing unrestricted flow from port 1 to tank port 2. It stays open as long as the pressure at port 1 exceeds that of port 2, and it resets only when flow ceases and the pressure at port 2 equals or exceeds that at port 1. The main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability. This cartridge is not intended for load-holding applications and should be used on the actuator side of the system since flow must stop for resetting. If applied on the pump side, pump flow needs to be halted for resetting purposes. The back pressure on tank port 2 directly adds to the valve setting in a 1:1 ratio. All two-port relief cartridges are interchangeable within a given frame size, offering flexibility in various setups. The corrosion-resistant design is suitable for harsh environments, with options for external stainless steel or zinc-nickel plated components identified by specific model code suffixes. Featuring Sun's floating style construction, this valve minimizes potential internal binding due to excessive installation torque or machining variations in cavity/cartridge interfaces. It operates with a maximum capacity of 25 gpm (95 L/min) and can withstand up to 5000 psi (350 bar). The typical response time is around 25 ms with minimal leakage under specified conditions. Installation requires specific torque settings for optimal performance, and an internal hex adjustment screw allows fine-tuning of pressure settings with multiple clockwise turns available for increasing settings if necessary.
The Sun Hydraulics RQEBJBV (RQEBJBV) is a kickdown relief cartridge designed to function similarly to a circuit breaker in an electrical system. This valve activates fully open when the pressure at inlet port 1 surpasses its set threshold, allowing unrestricted flow from port 1 to tank port 2. It stays open as long as the pressure at port 1 exceeds that of port 2, and it resets only when flow ceases and the pressure at port 2 equals or exceeds that at port 1. The main stage orifice is safeguarded by a 150-micron stainless steel screen, ensuring durability and reliability. This cartridge is not intended for load-holding applications and should be used on the actuator side of the system since flow must stop for resetting. If applied on the pump side, pump flow needs to be halted for resetting purposes. The back pressure on tank port 2 directly adds to the valve setting in a 1:1 ratio. All two-port relief cartridges are interchangeable within a given frame size, offering flexibility in various setups. The corrosion-resistant design is suitable for harsh environments, with options for external stainless steel or zinc-nickel plated components identified by specific model code suffixes. Featuring Sun's floating style construction, this valve minimizes potential internal binding due to excessive installation torque or machining variations in cavity/cartridge interfaces. It operates with a maximum capacity of 25 gpm (95 L/min) and can withstand up to 5000 psi (350 bar). The typical response time is around 25 ms with minimal leakage under specified conditions. Installation requires specific torque settings for optimal performance, and an internal hex adjustment screw allows fine-tuning of pressure settings with multiple clockwise turns available for increasing settings if necessary.
Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve settting, creating an unrestricted flow path from port 1 to tank (port 2). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.
- To reset valve, flow through the cartridge must cease.
- Main stage orifice is protected by a 150 micron stainless steel screen.
- Not suitable for use in load holding applications.
- Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
- Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
- All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-10A |
| Series | 1 |
| Capacity | 25 gpm95 L/min. |
| Factory Pressure Settings Established at | Kick down pointKick down point |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 25 ms25 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-010-006 |
Show FAQ
Additional Resources
- Tri-Grip Handknob Now Offered From Sun as a Standard Control Option
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Introduces 'Hybrid' Valves
- CE/TÜV Certified Pressure Relief Valves
- Pressure Relief and Regulating Cartridge Valve Technical Tips
- Pilot Operated, Balanced Poppet Relief Valves
- Sun Expands Corrosion-Resistant Solutions
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Pilot-Operated, Balanced Poppet, Anti Shock Reliefs
- CavitySaver multi-function valves deliver single-cartridge solutions
- 'Soft' Relief Eliminates Pressure Spikes
- Manufacturing Sun Cartridge Cavities
- Pressure Relief and Regulating Valves
- Cavity Information (S-171) and Tooling
- Sun Model Code Explanation; 999-901-334
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
Notes:
- Do not use in load holding applications.
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.