You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RQEBJDV


$80.32 USD
  • SUN HYDRAULICS
  • Material:RQEBJDV
  • Model:RQEB-JDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RQEBJDV (RQEBJDV) is a kickdown relief cartridge designed to function similarly to a circuit breaker in an electrical system. It activates by kicking completely open and remains open once the pressure at inlet port 1 surpasses the valve setting, allowing unrestricted flow from port 1 to tank port 2. The valve stays open as long as the pressure at port 1 exceeds that at port 2. For resetting, the flow from port 1 to port 2 must stop, and the pressure at port 2 must be equal to or greater than that at port 1. This cartridge is not suitable for load holding applications and is intended for use on the actuator side of systems, as flow must cease for resetting. If used on the pump side, pump flow must be shut off for reset. It features a main stage orifice protected by a 150-micron stainless steel screen and is corrosion-resistant with options for external stainless steel or zinc-nickel plated components. The valve has a maximum operating pressure of 5000 psi (350 bar), with a typical response time of 25 ms and maximum leakage of 2 in\u00b3/min (30 cc/min) at specified conditions. Adjustments can be made with up to five clockwise turns to increase settings, using specific hex sizes for installation and adjustment screws. Its compact design includes features like Sun's floating style construction to minimize internal part binding due to excessive torque or machining variations, making it reliable in various applications like portable grain augers where safety is crucial during operation interruptions.

Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve settting, creating an unrestricted flow path from port 1 to tank (port 2). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • To reset valve, flow through the cartridge must cease.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications.
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-10A
Series1
Capacity25 gpm95 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-010-006

Show FAQ

Additional Resources



Notes:
  • Do not use in load holding applications.
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.