You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RQGBCDV


$123.41 USD
  • SUN HYDRAULICS
  • Material:RQGBCDV
  • Model:RQGB-CDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RQGBCDV (RQGBCDV) is a kickdown relief cartridge designed to function similarly to a circuit breaker in hydraulic systems. Once the pressure at inlet port 1 exceeds the valve setting, this valve kicks completely open, allowing unrestricted flow from port 1 to tank port 2. It remains open as long as the pressure at port 1 surpasses that at port 2. To reset, flow between these ports must cease, with pressure at port 2 equal to or greater than at port 1. This cartridge is not suitable for load-holding applications and is best used on the actuator side of systems where flow cessation is feasible for resetting. For pump-side applications, pump flow must be halted for valve reset. The valve features a main stage orifice protected by a 150-micron stainless steel screen and incorporates Sun's floating style construction to minimize internal part binding from excessive installation torque or machining variations. It offers corrosion-resistant options identified by model code suffixes AP or LH for external stainless steel or zinc-nickel plated components, respectively. With a capacity of 50 gpm (200 L/min) and maximum operating pressure of 5000 psi (350 bar), it provides rapid response times typically around 25 ms. The maximum valve leakage is specified as 3 in\u00b3/min at 1000 psi (50 cc/min at 70 bar). Adjustment settings can be modified with five clockwise turns, using an internal hex size of 5/32 inches (4 mm). Installation requires a torque of 45-50 lbf-ft (61-68 Nm) with a locknut torque specification of 80-90 lbf-in (9-10 Nm). The model weighs .50 lb (.25 kg) and uses Viton seal kits for durability in various environments.

Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve settting, creating an unrestricted flow path from port 1 to tank (port 2). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • To reset valve, flow through the cartridge must cease.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications.
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-3A
Series2
Capacity50 gpm200 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.@1000 psi50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-203-006

Show FAQ

Additional Resources



Notes:
  • Do not use in load holding applications.
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.