***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RQGBFQV (RQGBFQV) is a kickdown relief cartridge designed to operate similarly to a circuit breaker in an electrical system. This hydraulic valve activates when the pressure at the inlet port exceeds its set threshold, allowing unrestricted flow from port 1 to tank port 2. The valve remains open as long as the pressure at port 1 surpasses that at port 2, and it resets only when flow ceases and pressure equalizes between the two ports. This design makes it suitable for use on the actuator side of a system, where flow cessation is required for resetting. It features a main stage orifice protected by a 150-micron stainless steel screen but is not recommended for load holding applications. The valve's construction includes corrosion-resistant options, identified by model code suffixes AP or LH, which are suitable for corrosive environments. It incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. With a capacity of 50 gpm (200 L/min) and maximum operating pressure of 5000 psi (350 bar), this cartridge offers reliable performance with minimal leakage. Installation specifications include a valve hex size of 1-1/8 inches (28.6 mm) and an installation torque range of 45-50 lbf ft (61-68 Nm). The adjustment screw features an internal hex size of 5/32 inches (4 mm), while the locknut has a hex size of 9/16 inches (15 mm) with a torque requirement of 80-90 lbf in (9-10 Nm). Weighing .50 lb (.25 kg), this model comes with a Viton seal kit option, ensuring compatibility with various hydraulic systems.

Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve settting, creating an unrestricted flow path from port 1 to tank (port 2). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • To reset valve, flow through the cartridge must cease.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications.
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-3A
Series2
Capacity50 gpm200 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.@1000 psi50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-203-006

Show FAQ

Additional Resources



Notes:
  • Do not use in load holding applications.