***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RQGBOCN (RQGBOCN) is a kickdown relief cartridge designed to function similarly to a circuit breaker within hydraulic systems. This valve completely opens and remains open when the pressure at inlet port 1 surpasses the set threshold, allowing unrestricted flow from port 1 to tank port 2. It stays open as long as the pressure at port 1 is greater than at port 2, and resets only when flow ceases and pressure equalizes between ports. This cartridge is interchangeable with other 2-port relief cartridges of the same frame size, making it versatile for various applications. It features a main stage orifice protected by a 150-micron stainless steel screen, though it is not recommended for load-holding applications. The valve should be used on the actuator side of systems since flow must stop for resetting; if used on the pump side, pump flow must cease for reset functionality. Back pressure on tank port 2 adds directly to the valve setting at a 1:1 ratio. The RQGBOCN incorporates Sun's floating style construction to reduce internal binding risks due to excessive torque or machining variations. With a capacity of 50 gpm (200 L/min) and maximum operating pressure of 5000 psi (350 bar), its typical response time is approximately 25 ms, with minimal leakage under specified conditions. Installation requires specific torque settings: valve hex size is 1-1/8 in., installation torque ranges from 45-50 lbf ft, adjustment screw internal hex size is 5/32 in., locknut hex size is 9/16 in., and locknut torque ranges from 80-90 lbf in. The model weighs .50 lb (.25 kg) and uses Viton seal kits for maintenance.

Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve settting, creating an unrestricted flow path from port 1 to tank (port 2). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • To reset valve, flow through the cartridge must cease.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications.
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-3A
Series2
Capacity50 gpm200 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.@1000 psi50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-203-006