You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RQGBODN


$124.90 USD
  • SUN HYDRAULICS
  • Material:RQGBODN
  • Model:RQGB-ODN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RQGBODN (RQGBODN) is a kickdown relief cartridge designed to function similarly to a circuit breaker in hydraulic systems. This valve activates by completely opening and maintaining an open state once the inlet port pressure surpasses the set valve threshold, allowing unrestricted flow from port 1 to tank port 2. The valve remains open as long as the pressure at port 1 exceeds that of port 2, and resets only when flow ceases and pressure at port 2 equals or exceeds that at port 1. These cartridges, except for pilot reliefs, are interchangeable with others of the same frame size, offering consistent flow paths and cavity dimensions. The main stage orifice is shielded by a durable 150-micron stainless steel screen, although these valves are unsuitable for load holding applications. They are intended for actuator-side use in systems where flow cessation is necessary for resetting; if installed on the pump side, pump flow must halt for reset functionality. Back pressure on tank port 2 directly adds to the valve setting at a one-to-one ratio. Corrosion-resistant options are available with external stainless steel or zinc-nickel plated components. The cartridge features Sun's floating style construction to mitigate internal part binding risks due to excessive installation torque or machining variations. With a cavity size of T-3A and series designation of 2, it has a capacity of up to 50 gpm (200 L/min) and operates at a maximum pressure of 5000 psi (350 bar). It offers typical response times around 25 ms with minimal leakage rates under specified conditions. Adjustments can be made via a screw with specific torque requirements, ensuring precise control over performance settings.

Kick-down relief cartridges act similar to a circuit breaker in an electrical system. The valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve settting, creating an unrestricted flow path from port 1 to tank (port 2). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, flow from port 1 to port 2 must cease and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • To reset valve, flow through the cartridge must cease.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications.
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-3A
Series2
Capacity50 gpm200 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.@1000 psi50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-203-006

Show FAQ

Additional Resources



Notes:
  • Do not use in load holding applications.
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.