SUN HYDRAULICS
RSDCFQV
$77.44 USD
- SUN HYDRAULICS
- Material:RSDCFQV
- Model:RSDC-FQV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RSDCFQV (RSDCFQV) is a pilot-operated, balanced piston sequence valve designed to supply a secondary circuit with flow once the pressure at the inlet port 1 surpasses the valve setting. This valve controls pressure at port 1 relative to the drain port 3 and remains unaffected by back pressure at port 2 up to the valve setting. It can be used as an alternative to 2-port relief valves when there is return line pressure. All three-port sequence cartridges are interchangeable, sharing the same flow path and cavity for a given frame size. As pressure at port 1 increases relative to port 3, pilot flow continues to rise above the valve setting. The main stage orifice is safeguarded by a 150-micron stainless steel screen, and pressure at port 3 adds directly to the valve setting in a 1:1 ratio, not exceeding 5000 psi (350 bar). The RSDCFQV is not suitable for load-holding applications due to spool leakage. The valve features corrosion-resistant options identified by model code suffixes AP or LH for external stainless steel or zinc-nickel plated components, respectively. It utilizes Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. With a cavity of T-11A and series of 1, it has a capacity of up to 15 gpm (60 L/min) with factory pressure settings established at 4 gpm (15 L/min). It operates under a maximum pressure of 5000 psi (350 bar) with control pilot flow between 7-10 in\u00b3/min (0.11-0.16 L/min) and typical response time of about 10 ms. Maximum leakage stands at approximately 2 in\u00b3/min under specific conditions. The adjustment requires around five clockwise turns for increased settings, with specific torque specifications for installation and adjustments provided within product details.
The Sun Hydraulics RSDCFQV (RSDCFQV) is a pilot-operated, balanced piston sequence valve designed to supply a secondary circuit with flow once the pressure at the inlet port 1 surpasses the valve setting. This valve controls pressure at port 1 relative to the drain port 3 and remains unaffected by back pressure at port 2 up to the valve setting. It can be used as an alternative to 2-port relief valves when there is return line pressure. All three-port sequence cartridges are interchangeable, sharing the same flow path and cavity for a given frame size. As pressure at port 1 increases relative to port 3, pilot flow continues to rise above the valve setting. The main stage orifice is safeguarded by a 150-micron stainless steel screen, and pressure at port 3 adds directly to the valve setting in a 1:1 ratio, not exceeding 5000 psi (350 bar). The RSDCFQV is not suitable for load-holding applications due to spool leakage. The valve features corrosion-resistant options identified by model code suffixes AP or LH for external stainless steel or zinc-nickel plated components, respectively. It utilizes Sun's floating style construction, minimizing internal part binding due to excessive installation torque or machining variations. With a cavity of T-11A and series of 1, it has a capacity of up to 15 gpm (60 L/min) with factory pressure settings established at 4 gpm (15 L/min). It operates under a maximum pressure of 5000 psi (350 bar) with control pilot flow between 7-10 in\u00b3/min (0.11-0.16 L/min) and typical response time of about 10 ms. Maximum leakage stands at approximately 2 in\u00b3/min under specific conditions. The adjustment requires around five clockwise turns for increased settings, with specific torque specifications for installation and adjustments provided within product details.
Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.
- All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
- Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
- The main stage orifice is protected by a 150 micron stainless steel screen.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Not suitable for use in load holding applications due to spool leakage.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 15 gpm60 L/min. |
| Factory Pressure Settings Established at | 4 gpm15 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Response Time - Typical | 10 ms10 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2 in³/min.@1000 psi30 cc/min.@70 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-011-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sequence Valves Technical Tips
- Manufacturing Sun Cartridge Cavities
- Sequence Valves
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
Notes:
- For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.