You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RSDCJBN


$67.51 USD
  • SUN HYDRAULICS
  • Material:RSDCJBN
  • Model:RSDC-JBN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RSDCJBN (RSDCJBN) is a pilot-operated, balanced piston sequence valve designed to supply a secondary circuit with flow once the pressure at the inlet port exceeds the valve setting. This sequence valve effectively controls pressure at port 1 relative to the pressure at drain port 3, remaining insensitive to back pressure at port 2 up to the set valve limit. It can serve as a substitute for two-port relief valves when there's pressure in the return line. Notably, all three-port sequence cartridges are interchangeable in terms of flow path and cavity size. The pilot flow increases as inlet pressure rises above the valve setting relative to drain pressure. The main stage orifice is safeguarded by a 150-micron stainless steel screen, and pressure at port 3 is directly additive to the valve setting at a 1:1 ratio, with a maximum limit of 5000 psi (350 bar). This model is unsuitable for load-holding applications due to spool leakage. The RSDCJBN incorporates Sun's floating style construction, minimizing internal part binding from excessive installation torque or machining variations. It features corrosion-resistant options identified by suffixes \"AP\" for stainless steel components or \"LH\" for zinc-nickel plating. With a capacity of 15 gpm (60 L/min) and factory settings established at 4 gpm (15 L/min), it has a maximum operating pressure of 5000 psi (350 bar) and control pilot flow ranging from 7-10 in\u00b3/min (0.11-0.16 L/min). The response time is typically around 10 ms, and maximum valve leakage is specified at 2 in\u00b3/min (30 cc/min) under certain conditions. Installation requires specific torque settings for various components, ensuring optimal performance and reliability in diverse applications where precise sequencing is essential.

Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Not suitable for use in load holding applications due to spool leakage.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established at4 gpm15 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Response Time - Typical10 ms10 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.