You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RSDCQCV


$86.37 USD
  • SUN HYDRAULICS
  • Material:RSDCQCV
  • Model:RSDC-QCV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RSDCQCV (RSDCQCV) is a pilot-operated, balanced piston sequence valve designed to supply a secondary circuit with flow once the pressure at the inlet port 1 exceeds the valve setting. This sequence valve controls the pressure at port 1 relative to the drain port 3 and is insensitive to back pressure at port 2, up to the set valve pressure. It can be used as an alternative to two-port relief valves if there is pressure in the return line. The RSDCQCV features interchangeable three-port sequence cartridges, allowing for consistent flow paths and cavity compatibility within a given frame size. The valve's main stage orifice is protected by a 150-micron stainless steel screen, ensuring durability and reliability. The maximum operating pressure for this model is 5000 psi (350 bar), with a control pilot flow ranging from 7 to 10 in\u00b3/min (0.11 to 0.16 L/min). It offers a typical response time of 10 ms and has a maximum leakage rate of 2 in\u00b3/min (30 cc/min) at 1000 psi (70 bar). The valve can be adjusted through its full range using W or Y controls, with optional special settings available for maximum adjustment limits. It incorporates Sun's floating style construction, minimizing internal part binding due to installation torque or machining variations. The RSDCQCV model weighs approximately .30 lb (0.15 kg) and requires an installation torque of 30-35 lbf ft (41-47 Nm). The adjustment screw features an internal hex size of 5/32 in. (4 mm), while the locknut has a hex size of 9/16 in. (15 mm) with a torque requirement of 80-90 lbf in. (9-10 Nm). For those requiring corrosion resistance, options include external stainless steel components or zinc-nickel plating identified by specific model code suffixes such as AP or LH.

Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Not suitable for use in load holding applications due to spool leakage.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established at4 gpm15 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Response Time - Typical10 ms10 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.