***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RSFCLDE (RSFCLDE) is a pilot-operated, balanced piston sequence valve designed to manage secondary circuit flow once the inlet port pressure surpasses the valve's set threshold. It effectively controls pressure at port 1 relative to the drain port 3, remaining unaffected by back pressure at port 2 up to the valve setting. This valve can substitute for 2-port relief valves in systems with return line pressure. Notably, all three-port sequence cartridges are interchangeable regarding flow path and cavity size for a specific frame size. The valve's main stage orifice is safeguarded by a 150-micron stainless steel screen, and it can handle pressures up to 5000 psi (350 bar) at port 3, which directly adds to the valve setting at a 1:1 ratio. Due to spool leakage, this model is unsuitable for load-holding applications. The RSFCLDE features adjustable W and Y controls that can be set throughout their full range unless specified otherwise for a maximum setting. Cartridges with EPDM seals are designed for phosphate ester fluid systems and should not contact petroleum-based substances. The Sun floating style construction minimizes internal binding risks from excessive installation torque or machining variations. The RSFCLDE has a capacity of 30 gpm (120 L/min) with factory pressure settings established at 4 gpm (15 L/min). It boasts a maximum operating pressure of 5000 psi (350 bar) and control pilot flow between 10 - 15 in\u00b3/min (0.16 - 0.25 L/min). Typical response time is around 10 ms, with maximum leakage of approximately 3 in\u00b3/min at 110 SUS (24 cSt). Installation requires specific torque settings and hex sizes for adjustment screws and locknuts, ensuring secure fitting and reliable performance in hydraulic systems.

Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence), up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in the return line.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Not suitable for use in load holding applications due to spool leakage.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established at4 gpm15 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Response Time - Typical10 ms10 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.@1000 psi50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.