You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RVCAKEV


$100.77 USD
  • SUN HYDRAULICS
  • Material:RVCAKEV
  • Model:RVCA-KEV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RVCAKEV (RVCAKEV) is a ventable, pilot-operated, balanced piston relief cartridge designed to regulate pressure in hydraulic systems. This normally closed valve opens to the tank port when the inlet pressure reaches the set level, effectively throttling flow to maintain desired pressure levels. It features a vent port that allows for remote control by other pilot or two-way valves. Known for its accuracy and low-pressure rise versus flow characteristics, this valve operates smoothly and quietly with moderate speed. The RVCAKEV can handle maximum pressure at port 2 and is suitable for cross-port relief circuits, though spool leakage should be considered in such applications. It includes a 150-micron stainless steel screen protecting the main stage orifice but is not suitable for load-holding applications due to spool leakage issues. The valve's back pressure on tank port 2 directly adds to the valve setting at a 1:1 ratio. Configured with EPDM seals, it is compatible with systems using phosphate ester fluids but not with petroleum-based fluids, greases, or lubricants which can cause seal damage. The floating style construction minimizes potential binding of internal parts due to excessive installation torque or machining variations. This Series 1 cartridge has a capacity of 15 gpm (60 L/min) and operates at a maximum pressure of 5000 psi (350 bar). Control pilot flow ranges from 7-10 in\u00b3/min (0.11-0.16 L/min), with typical response times around 10 ms. Maximum valve leakage at 110 SUS (24 cSt) is about 2 in\u00b3/min at 1000 psi (30 cc/min at 70 bar). The adjustment mechanism allows up to five clockwise turns to increase settings, while installation requires specific torques for both the valve and locknut components.

Ventable, pilot-operated, balanced piston relief cartridges are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. They provide a vent port (port 3) that connects between the main piston and pilot stage to provide for remote control by other pilot or 2-way valves. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

  • A remote pilot relief on port 3 (vent) will control the valve below its own setting.
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications due to spool leakage.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established at4 gpm15 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Response Time - Typical10 ms10 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.