SUN HYDRAULICS
RVEBJDV
$150.81 USD
- SUN HYDRAULICS
- Material:RVEBJDV
- Model:RVEB-JDV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RVEBJDV (RVEBJDV) is a three-port normally closed modulating element with relief capabilities, designed to provide dual functions when combined with an external orifice. This valve acts as a bypass compensator, controlling priority flow into the circuit as determined by the external orifice, while excess input flow is redirected to tank port 2. Additionally, if the pressure at inlet port 1 exceeds the valve setting, it functions as a standard relief valve. The compensating pressure for all ranges is set at 120 psi (8 bar). The performance curve illustrates that system pressure on the X-axis and the pressure differential across the control orifice on the Y-axis are influenced by various bypass flows; notably, control flow does not impact capacity and performance. The valve supports W and Y controls for adjustable settings across its range, with options for special settings representing maximum valve limits. Key specifications include a cavity size of T-2A Series 2 with a capacity of 20 gpm (80 L/min), maximum operating pressure of 5000 psi (350 bar), typical response time of 10 ms, and maximum valve leakage at specified conditions being 3 in\u00b3/min (50 cc/min). Adjustment features include up to five clockwise turns to increase settings, with installation torque requirements of 45 - 50 lbf ft (61 - 68 Nm). The model weighs .70 lb (.30 kg) and includes Viton seal kits for effective sealing solutions.
The Sun Hydraulics RVEBJDV (RVEBJDV) is a three-port normally closed modulating element with relief capabilities, designed to provide dual functions when combined with an external orifice. This valve acts as a bypass compensator, controlling priority flow into the circuit as determined by the external orifice, while excess input flow is redirected to tank port 2. Additionally, if the pressure at inlet port 1 exceeds the valve setting, it functions as a standard relief valve. The compensating pressure for all ranges is set at 120 psi (8 bar). The performance curve illustrates that system pressure on the X-axis and the pressure differential across the control orifice on the Y-axis are influenced by various bypass flows; notably, control flow does not impact capacity and performance. The valve supports W and Y controls for adjustable settings across its range, with options for special settings representing maximum valve limits. Key specifications include a cavity size of T-2A Series 2 with a capacity of 20 gpm (80 L/min), maximum operating pressure of 5000 psi (350 bar), typical response time of 10 ms, and maximum valve leakage at specified conditions being 3 in\u00b3/min (50 cc/min). Adjustment features include up to five clockwise turns to increase settings, with installation torque requirements of 45 - 50 lbf ft (61 - 68 Nm). The model weighs .70 lb (.30 kg) and includes Viton seal kits for effective sealing solutions.
Three-port normally closed modulating elements with relief provide two functions when combined with an external orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure rises to the valve setting, the valve operates as a normal relief valve.
- Compensating pressure for all ranges is 120 psi (8 bar).
- Explanation of the performance curve: The X axis is system pressure. The Y axis shows the pressure differential that the valve creates across the control orifice. The curves represent various bypass flows (pump flow minus control flow). The capacity and performance of this valve is determined by the bypass flow, control flow is not a factor.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | 4 gpm15 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 10 ms10 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 3 in³/min.@1000 psi50 cc/min.@70 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .70 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Manufacturing Sun Cartridge Cavities
- Cartridges: Materials of Construction
- Cavity Information (S-171) and Tooling
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Performance Data
- Sun Model Code Explanation; 999-901-334
- Units of Measure, Settings, and Conversions