SUN HYDRAULICS
SCEAKCN
$149.91 USD
- SUN HYDRAULICS
- Material:SCEAKCN
- Model:SCEA-KCN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SCEAKCN (SCEAKCN) is a direct-acting sequence valve equipped with a reverse flow check, designed to supply a secondary circuit with flow once the inlet port 1 pressure surpasses the valve setting. This model includes an integral check valve for reverse flow from port 2 to port 1. The sequence valve's pressure setting regulates the pressure at port 1 relative to the drain port 3, and it is crucial that port 3 remains connected to maintain a pressure reference in the control chamber; blocking it can lead to malfunction due to reciprocating seal weepage. The pressure at port 3 directly adds to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Suitable for load-holding applications, this valve features interchangeable three-port sequence cartridges with consistent flow paths and cavities for given frame sizes. Sun's floating style construction minimizes internal part binding risks due to installation torque or cavity machining variations. With a capacity of 30 gpm (120 L/min) and maximum operating pressure of 5000 psi (350 bar), this model offers typical response times of about 2 ms. The maximum valve leakage at reseat is limited to 10 drops/min (0.7 cc/min), while the check cracking pressure is set at 25 psi (1.7 bar). Adjustment involves up to five clockwise turns to increase settings, with specific hex sizes for installation and adjustment screws, as well as locknut torque specifications. Weighing .60 lb (.30 kg), this model uses Viton seal kits and incorporates design elements like zinc-nickel plating for enhanced corrosion resistance and compatibility with EPDM seals in certain configurations.
The Sun Hydraulics SCEAKCN (SCEAKCN) is a direct-acting sequence valve equipped with a reverse flow check, designed to supply a secondary circuit with flow once the inlet port 1 pressure surpasses the valve setting. This model includes an integral check valve for reverse flow from port 2 to port 1. The sequence valve's pressure setting regulates the pressure at port 1 relative to the drain port 3, and it is crucial that port 3 remains connected to maintain a pressure reference in the control chamber; blocking it can lead to malfunction due to reciprocating seal weepage. The pressure at port 3 directly adds to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Suitable for load-holding applications, this valve features interchangeable three-port sequence cartridges with consistent flow paths and cavities for given frame sizes. Sun's floating style construction minimizes internal part binding risks due to installation torque or cavity machining variations. With a capacity of 30 gpm (120 L/min) and maximum operating pressure of 5000 psi (350 bar), this model offers typical response times of about 2 ms. The maximum valve leakage at reseat is limited to 10 drops/min (0.7 cc/min), while the check cracking pressure is set at 25 psi (1.7 bar). Adjustment involves up to five clockwise turns to increase settings, with specific hex sizes for installation and adjustment screws, as well as locknut torque specifications. Weighing .60 lb (.30 kg), this model uses Viton seal kits and incorporates design elements like zinc-nickel plating for enhanced corrosion resistance and compatibility with EPDM seals in certain configurations.
Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).
- Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Suitable for use in load holding applications.
- All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 30 gpm120 L/min. |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 2 ms2 ms |
| Maximum Valve Leakage at Reseat | 10 drops/min.0,7 cc/min. |
| Check Cracking Pressure | 25 psi1,7 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .60 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- Sequence Valves Technical Tips
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Manufacturing Sun Cartridge Cavities
- Sequence Valves
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data