SUN HYDRAULICS
SCGACWV
$272.32 USD
- SUN HYDRAULICS
- Material:SCGACWV
- Model:SCGA-CWV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SCGACWV (SCGACWV) is a direct-acting sequence valve with an integrated reverse-flow check valve, designed to supply a secondary circuit with flow once the inlet port 1 pressure surpasses the valve setting. This model ensures reverse flow from port 2 to port 1 via its integral check valve. It controls pressure at port 1 relative to the drain port 3 and requires connection of port 3 to maintain proper pressure reference in the control chamber. Blocking port 3 can lead to malfunction due to seal weepage. The pressure at port 3 should not exceed 5000 psi, as it is additive to the valve setting at a 1:1 ratio. The SCGACWV is suitable for load-holding applications and incorporates Sun's floating-style construction, reducing internal part binding risks due to excessive torque or machining variations. This sequence valve fits into a Cavity T-17A series and has a capacity of up to 60 gpm (240 L/min). It operates effectively under maximum pressures of up to 5000 psi (350 bar) and has typical response times of around 2 ms. The maximum leakage at reseat is limited to 10 drops/min (0.7 cc/min), and it features a check cracking pressure of approximately 25 psi (1.7 bar). The adjustment mechanism allows for increasing settings through five full clockwise turns, with specific dimensions for installation torque and adjustment screws provided for accurate setup. The model weighs approximately 1.50 lb (0.70 kg) and utilizes Viton seals, available under seal kit number: 990017006, ensuring durability and reliability in various hydraulic applications.
The Sun Hydraulics SCGACWV (SCGACWV) is a direct-acting sequence valve with an integrated reverse-flow check valve, designed to supply a secondary circuit with flow once the inlet port 1 pressure surpasses the valve setting. This model ensures reverse flow from port 2 to port 1 via its integral check valve. It controls pressure at port 1 relative to the drain port 3 and requires connection of port 3 to maintain proper pressure reference in the control chamber. Blocking port 3 can lead to malfunction due to seal weepage. The pressure at port 3 should not exceed 5000 psi, as it is additive to the valve setting at a 1:1 ratio. The SCGACWV is suitable for load-holding applications and incorporates Sun's floating-style construction, reducing internal part binding risks due to excessive torque or machining variations. This sequence valve fits into a Cavity T-17A series and has a capacity of up to 60 gpm (240 L/min). It operates effectively under maximum pressures of up to 5000 psi (350 bar) and has typical response times of around 2 ms. The maximum leakage at reseat is limited to 10 drops/min (0.7 cc/min), and it features a check cracking pressure of approximately 25 psi (1.7 bar). The adjustment mechanism allows for increasing settings through five full clockwise turns, with specific dimensions for installation torque and adjustment screws provided for accurate setup. The model weighs approximately 1.50 lb (0.70 kg) and utilizes Viton seals, available under seal kit number: 990017006, ensuring durability and reliability in various hydraulic applications.
Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).
- All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
- Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Suitable for use in load holding applications.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-17A |
| Series | 3 |
| Capacity | 60 gpm240 L/min. |
| Factory Pressure Settings Established at | 2 in³/min.30 cc/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 2 ms2 ms |
| Maximum Valve Leakage at Reseat | 10 drops/min.0,7 cc/min. |
| Check Cracking Pressure | 25 psi1,7 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.50 lb0,70 kg |
| Seal kit - Cartridge | Viton: 990-017-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Sun Expands Corrosion-Resistant Solutions
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sequence Valves Technical Tips
- Manufacturing Sun Cartridge Cavities
- Sequence Valves
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions