You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQDBCDN


$103.05 USD
  • SUN HYDRAULICS
  • Material:SQDBCDN
  • Model:SQDB-CDN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQDBCDN (Material Number: SQDBCDN) is a specialized kickdown sequence valve designed to open completely and maintain an open state when the inlet port 1 pressure surpasses the valve setting, facilitating unrestricted flow from port 1 to port 2. This mechanism is contingent on the pressure at port 1 being higher than at port 2. Resetting the valve requires that the pressure at port 1 falls below its set threshold, with no flow from port 1 to port 2, and equal or higher pressure at port 2 compared to port 1. These valves are physically and functionally interchangeable across all three-port sequence cartridges of the same frame size but are not recommended for load-holding applications. The main stage orifice is safeguarded by a 150-micron stainless steel screen, and any pressure at port 3 adds directly to the valve setting in a one-to-one ratio, with an upper limit of 5000 psi (350 bar). Designed for actuator-side usage in systems where flow cessation through the valve is required for resetting, these valves are corrosion-resistant, available with external stainless steel (suffix AP) or zinc-nickel plated components (suffix LH). They incorporate Sun's floating style construction to reduce internal part binding from excessive installation torque or machining variations. The valve features a cavity size of T-11A Series 1, with a capacity of up to 15 gpm (60 L/min), and factory settings established at kickdown points. It operates efficiently under a maximum pressure of 5000 psi (350 bar) with typical response times around 25 ms and minimal leakage rates. Installation specifications include a hex size of .78 inches (22.2 mm) and installation torque between 30-35 lbf-ft (41-47 Nm).

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.30 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.