You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQDBLDV


$103.05 USD
  • SUN HYDRAULICS
  • Material:SQDBLDV
  • Model:SQDB-LDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQDBLDV (SQDBLDV) is a kickdown sequence valve designed to open completely and remain open once the pressure at the inlet port 1 surpasses the valve setting, facilitating an unrestricted flow path from port 1 to port 2. The valve's operation is contingent on the pressure conditions at various ports, with its setting being relative to drain port 3. Notably, this valve remains open as long as the pressure at port 1 exceeds that at port 2. To reset it, the pressure at port 1 must drop below its setting, and flow must cease between ports 1 and 2 while ensuring pressure equilibrium between these ports. This model is interchangeable with all other three-port sequence cartridges of similar frame size in terms of flow path and cavity dimensions but is not suited for load-holding applications. Built with corrosion-resistant materials, this cartridge can operate in harsh environments and includes a stainless steel screen protecting its main stage orifice. The maximum allowable pressure at port 3 is additive to the valve setting, up to a limit of 5000 psi (350 bar). It is primarily intended for use on the actuator side of hydraulic systems since flow cessation through the valve is necessary for resetting; if used on the pump side, pump flow must be halted for resetting. The SQDBLDV incorporates Sun's floating style construction to prevent internal binding due to installation torque or machining variations. It has a capacity of up to 15 gpm (60 L/min) and features a factory pressure setting established at its kickdown point, with maximum operating pressures reaching up to 5000 psi (350 bar). The response time typically measures around 25 ms, and it exhibits minimal leakage under specified conditions.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.30 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.