***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQDBOCV (SQDBOCV) is a kickdown sequence valve designed to open completely and remain open when the pressure at inlet port 1 surpasses the valve setting, allowing unrestricted flow from port 1 to port 2. This flow path remains open as long as the pressure at port 1 is higher than at port 2. To reset the valve, the pressure at port 1 must drop below its setting, and flow must cease with equal or greater pressure maintained at port 2 compared to port 1. This model is part of a series where all three-port sequence cartridges are interchangeable in terms of flow path and cavity for a given frame size, although it is not suitable for load holding applications. The main stage orifice features a protective 150-micron stainless steel screen. The SQDBOCV is intended for use on the actuator side of systems due to its requirement that flow through the valve must stop for resetting, which makes it less effective on the pump side unless pump flow can be halted. It incorporates corrosion-resistant options identified by suffixes AP or LH in its model code, suitable for corrosive environments. The floating style construction minimizes internal binding risks due to installation torque and machining variations. This valve has a capacity of up to 15 gpm (60 L/min) with a maximum operating pressure of 5000 psi (350 bar). Typical response time is around 25 ms with minimal leakage rates under specified conditions. Installation requires specific torque settings and adjustments via an internal hex adjustment screw. The SQDBOCV weighs approximately .40 lb (.20 kg) and uses Viton seals identified by seal kit number 990011006.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.30 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.