You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQDBOWV


$116.95 USD
  • SUN HYDRAULICS
  • Material:SQDBOWV
  • Model:SQDB-OWV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQDBOWV (Material Number: SQDBOWV) is a kickdown sequence valve designed to manage hydraulic flow by opening fully and remaining open once the pressure at inlet port 1 surpasses the valve setting, allowing unrestricted flow from port 1 to port 2. This valve is suitable for applications where maintaining open flow under specific pressure conditions is crucial. It operates with a pressure setting at port 1 relative to drain port 3 and stays open as long as the pressure at port 1 exceeds that at port 2. To reset, the pressure at port 1 must drop below the valve setting, and flow from port 1 to port 2 must halt with equal or greater pressure at port 2 compared to port 1. The SQDBOWV features interchangeable three-port sequence cartridges, ensuring compatibility with other components of similar frame size. It should not be used in load-holding applications due to its design characteristics. The main stage orifice is safeguarded by a stainless steel screen with a mesh size of 150 microns. The valve setting can be influenced directly by the pressure at port 3, which should not exceed a maximum of 5000 psi (350 bar). Designed for actuator-side use in hydraulic systems, it requires cessation of flow for resetting when used on pump-side systems. This cartridge valve incorporates corrosion-resistant materials, identified by model code suffixes AP or LH for external stainless steel or zinc-nickel plated components respectively. Its floating style construction minimizes internal part binding risks due to installation torque or machining variations. The cavity T-11A Series accommodates a capacity of up to 15 gpm (60 L/min) with factory pressure settings determined at the kickdown point and offers a typical response time of approximately 25 ms.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.30 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes: