You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQFBCDV


$153.88 USD
  • SUN HYDRAULICS
  • Material:SQFBCDV
  • Model:SQFB-CDV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBCDV (SQFBCDV) is a specialized kickdown sequence valve designed to open completely and maintain an open state once the inlet port 1 pressure surpasses the valve's set threshold, allowing unrestricted flow from port 1 to port 2. This valve remains open as long as the pressure at port 1 exceeds that at port 2. To reset, the pressure at port 1 must drop below the valve setting, flow from port 1 to port 2 must stop, and pressure at port 2 must be equal to or greater than that at port 1. The SQFBCDV is interchangeable with all three-port sequence cartridges of similar frame size regarding flow path and cavity, but it is not suitable for load-holding applications. It features a stainless steel screen protecting its main stage orifice and supports a maximum operating pressure of up to 5000 psi (350 bar). The valve's design incorporates Sun's floating style construction, reducing the risk of internal part binding due to excessive torque or machining variations. It is intended for use on an actuator side of a system where flow cessation allows for reset; if used on a pump side, pump flow must be stopped for resetting. The valve has a capacity of up to 30 gpm (120 L/min), with factory pressure settings established at the kickdown point and typical response time around 25 ms. Maximum leakage at specific viscosity conditions is minimal, ensuring efficient operation. Installation requires specific torque values for both the valve itself and its adjustment components, with precise adjustments achievable through defined turns of its adjustment screw.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.