You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
SQFBJCN


$137.01 USD
  • SUN HYDRAULICS
  • Material:SQFBJCN
  • Model:SQFB-JCN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SQFBJCN (SQFBJCN) is a versatile kickdown sequence valve designed to manage fluid flow in hydraulic systems efficiently. This valve kicks completely open and remains open when the pressure at inlet port 1 exceeds the preset valve setting, allowing unrestricted flow from port 1 to port 2. The valve's operation is dependent on the pressure differential between ports, specifically requiring that the pressure at port 1 remains higher than that at port 2 to stay open. To reset the valve, the pressure at port 1 must drop below its set point, and flow from port 1 to port 2 must halt. The design incorporates Sun's floating style construction, minimizing internal binding risks due to installation torque or machining variations. This sequence valve should not be used for load holding applications as it requires cessation of flow for resetting. It features a main stage orifice protected by a durable 150-micron stainless steel screen and can handle pressures up to a maximum of 5000 psi (350 bar). With a capacity of handling up to 30 gpm (120 L/min), it provides reliable performance in various hydraulic applications. The SQFBJCN model also offers quick response times typically around 25 ms and maintains low leakage rates at maximum operating conditions. The unit is designed for easy interchangeability with other three-port sequence cartridges within its series, sharing identical flow paths and cavity dimensions for consistent integration into existing systems. Installation considerations include maintaining appropriate torque settings between 45-50 lbf ft (61-68 Nm) and ensuring compatibility with Viton seal kits for optimal performance.

Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1) exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.

  • All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Should not be used in load holding applications.
  • The main stage orifice is protected by a 150 micron stainless steel screen.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Intended for use on the actuator side of the system as flow through the valve must cease for the valve to reset. If used on the pump side of a system, pump flow must be shut off for the valve to reset.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-2A
Series2
Capacity30 gpm120 L/min.
Factory Pressure Settings Established atKick down pointKick down point
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical25 ms25 ms
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.50 lb0,25 kg
Seal kit - CartridgeViton: 990-202-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.